Product Main

Specifications

 

 
diesel generator with open frame
1sinlge or3 phase
2,1500/1800rpm
3.CE,ISO ,40kw
4silent type,380v,100%copper 
5.steady power in working time
 
Specification
 

 

Model WY-CM50(S) WY-CM57(S)
Cont.AC outpu(KW) 40 45 45 50
Max.output(KW) 45 50 50 55
Voltage(V) 220/380 220/380
Frequency(Hz) 50 60 50 60
Power factor 0.8 0.8
GENERATOR  Model WY224D WY224E
Cont.AC output(KW) 40 45 50 55
Max.output(KW) 45 50 55 60
Excitation SyStem  Brushless excitation   Brushless excitation 
InSulation Class H H
ConStruction Type  SAE engine adaptor (single-bearing or double-bearing) SAE engine adaptor (single-bearing or double-bearing)
ENGINE                               Model 4BTA3.9-G2 4BTA3.9-G2
Number of cylinders 4L 4L
Bore×stroke(mm) 102×120 102×120
Compression Ratio    
Displacement(L) 3.9 3.9
Specific fuel consumption 
(g/kW.h)
≤209 ≤209
Rated speed(r/min) 1500 1800 1500 1800
Cont.output(kW) 50 55 50.0 55
Max.outout(kW) 55 60 55 60
Starting system Electric Electric
Cooling method Closed circle water-cooled Closed circle water-cooled
Starting battery 12V/120AH 12V/120AH
Gensetfor protection The protection of low accumulator,overspeed,high water temperature,low press-gas  The protection of low accumulator,overspeed,high water temperature,low press-gas 
Cont.working time(h) 12 12
Overall dimensions(mm) 2250*950*1150 2250*950*1150
Package dimensions(mm) 2350*1000*1220 2350*1000*1220
Net weight(kg) 1120 1150
Dry weight(kg) 1170
1. ATS(Automatic Transfer switch), it can start generator set when the main power is off, once the main power comes back, the generator set will turn off automaticly.
And ATS have the function of AMF (automatic Main power failure)
 
2. MCCB(Molded case circuit breaker)
It can protect the loading machine and the diesel generator.
 
3. Battery charger(float charger)
When the generator hasn't been used for a long time, the batteries will be no power, in that way, you can't start the generator, but the battery charger can charge the batteries from the main power.
 
4. Extra daily fuel tank
It will be requested while the base fuel tank capacity is not enough for daily fuel consumption
 
5. Paralleling system
This system can make several generators work together and automatically distribute the load according to set.
 
6. Remote Control Panel
Which can control the generator by computer, if use a RS484 or RS232 digital cable to connect the generator to the computer.
 
7. Water separate(additional cooling system)
If the ambient temperature is too high, it will be harmful to the diesel generator. Fan and water cooling is not enough for radiate. The water separate system is much better for cooling, and the life of generator will be much longer.
 
8. Spare Parts of Cummins engine
All the spare parts of each Cummins engine are supplied at very competitive price.
Generator Supply Scope:

1.Engine, alternator, radiator, auto control panel.
2.Base frame, base fuel tank,Flexible pipes, flange, exhaust silencer .
3.Battery, battery charger, battery wires, internal cables, circuit breaker.
4.Manual books of engine, alternator, genset, control panel, wires diagram.

Engine:

1.Cummins : 6LTAA8.9-G2
2.Displacement:: 14 L
3.Cylinder quantity :6Cylinder
4.Fuel consumption: 192g/kw.h
5.Cooling Method: Water-cooled
6.Air intake way: Turbo-charged
7.Coolant capacity - engine only:20.8L
8.Governor method: Electrical Governor
Alternator:

1.Bearing: Single
2.Insulation Class: H
3.Phase: 3 Phase 4 wires
4.Protection Degree: IP 23
5.Excitation way: Brushless excitationing
6.Leroy somer, Stamford, Marathon for you choose
Other Optional part:
 
Warranty
12 months or 1000 running hours from shipment date. If the quality problem arise during the warranty period,and verified the problem is caused by our genset-body instead of external or natural reasons. (Refer to all kinds of natural disaster, shipping, loading, unloading, wrong-operation, etc), we will supply the relevant spare parts free of charge for maintenance; after the warranty period, we can supply the required spare parts for you under cost prices