remote control diesel generator genset
1top qualty,factory price
2 Cummins silent generator
2 Cummins silent generator
3single or 3 phase
4cummins engine.50hz/1500rpm
4cummins engine.50hz/1500rpm
5.1year warranty&best arfter service
6.steady power in working time
Cummins diesel generator specification
Model | WY-CM50(S) | ||
Cont.AC outpu(KW) | 40 | 45 | |
Max.output(KW) | 45 | 50 | |
Voltage(V) | 220/380 | ||
Frequency(Hz) | 50 | 60 | |
Power factor | 0.8 | ||
GENERATOR | Model | WY224D | |
Cont.AC output(KW) | 40 | 45 | |
Max.output(KW) | 45 | 50 | |
Excitation SyStem | Brushless excitation | ||
InSulation Class | H | ||
ConStruction Type | SAE engine adaptor (single-bearing or double-bearing) | ||
ENGINE | Model | 4BTA3.9-G2 | |
Number of cylinders | 4L | ||
Bore×stroke(mm) | 102×120 | ||
Compression Ratio | |||
Displacement(L) | 3.9 | ||
Specific fuel consumption (g/kW.h) |
≤209 | ||
Rated speed(r/min) | 1500 | 1800 | |
Cont.output(kW) | 50 | 55 | |
Max.outout(kW) | 55 | 60 | |
Starting system | Electric | ||
Cooling method | Closed circle water-cooled | ||
Starting battery | 12V/120AH | ||
Gensetfor protection | The protection of low accumulator,overspeed,high water temperature,low press-gas | ||
Cont.working time(h) | 12 | ||
Overall dimensions(mm) | 2250*950*1150 | ||
Package dimensions(mm) | 2350*1000*1220 | ||
Net weight(kg) | 1120 | ||
Dry weight(kg) | 1170 |
Packing dimension
CONTAINER | Capacity | Recommended | |||||
Load Volume | |||||||
Nominal | Length | Width | Height | Cubic | Cubic | Cubic | Cubic |
Dimension | Feet | Meter | Feet | Meter | |||
External | 20' | 8' | 8' 6" | ||||
6.096 m | 2.438 m | 2.591 m | |||||
Internal | 19' 4.25" | 7' 8.625" | 7' 10" | 1170 cft | 1000 cft | ||
5.899 m | 2.353 m | 2.388 m | 33.131 cbm | 28 cbm | |||
External | 40' | 8' | 8' 6" | ||||
12.192 m | 2.438 m | 2.591 m | |||||
Internal | 39' 5.375" | 7' 8.625" | 7' 10" | 2385 cft | 2050 cft | ||
12.024 m | 2.353 m | 2.388 m | 67.535 cbm | 58 cbm | |||
External | 40' Hicube | 8' | 9' 6" | ||||
12.192 m | 2.438 m | 2.896 m | |||||
Internal | 39' 5.375" | 7' 8.625" | 8' 10" | 2690 cft | 2350 cft | ||
12.024 m | 2.353 m | 2.692 m | 76.172 cbm | 66 cbm |
1. ATS(Automatic Transfer switch), it can start generator set when the main power is off, once the main power comes back, the generator set will turn off automaticly.
And ATS have the function of AMF (automatic Main power failure)
2. MCCB(Molded case circuit breaker)
It can protect the loading machine and the diesel generator.
3. Battery charger(float charger)
When the generator hasn't been used for a long time, the batteries will be no power, in that way, you can't start the generator, but the battery charger can charge the batteries from the main power.
4. Extra daily fuel tank
It will be requested while the base fuel tank capacity is not enough for daily fuel consumption
5. Paralleling system
This system can make several generators work together and automatically distribute the load according to set.
6. Remote Control Panel
Which can control the generator by computer, if use a RS484 or RS232 digital cable to connect the generator to the computer.
7. Water separate(additional cooling system)
If the ambient temperature is too high, it will be harmful to the diesel generator. Fan and water cooling is not enough for radiate. The water separate system is much better for cooling, and the life of generator will be much longer.
8. Spare Parts of Cummins engine
All the spare parts of each Cummins engine are supplied at very competitive price.
Generator Supply Scope:
1.Engine, alternator, radiator, auto control panel.
2.Base frame, base fuel tank,Flexible pipes, flange, exhaust silencer .
3.Battery, battery charger, battery wires, internal cables, circuit breaker.
4.Manual books of engine, alternator, genset, control panel, wires diagram.
Engine:
1.Cummins : 6LTAA8.9-G2
2.Displacement:: 14 L
3.Cylinder quantity :6Cylinder
4.Fuel consumption: 192g/kw.h
5.Cooling Method: Water-cooled
6.Air intake way: Turbo-charged
7.Coolant capacity - engine only:20.8L
8.Governor method: Electrical Governor
1.Engine, alternator, radiator, auto control panel.
2.Base frame, base fuel tank,Flexible pipes, flange, exhaust silencer .
3.Battery, battery charger, battery wires, internal cables, circuit breaker.
4.Manual books of engine, alternator, genset, control panel, wires diagram.
Engine:
1.Cummins : 6LTAA8.9-G2
2.Displacement:: 14 L
3.Cylinder quantity :6Cylinder
4.Fuel consumption: 192g/kw.h
5.Cooling Method: Water-cooled
6.Air intake way: Turbo-charged
7.Coolant capacity - engine only:20.8L
8.Governor method: Electrical Governor
Alternator:
1.Bearing: Single
2.Insulation Class: H
3.Phase: 3 Phase 4 wires
4.Protection Degree: IP 23
5.Excitation way: Brushless excitationing
6.Leroy somer, Stamford, Marathon for you choose
1.Bearing: Single
2.Insulation Class: H
3.Phase: 3 Phase 4 wires
4.Protection Degree: IP 23
5.Excitation way: Brushless excitationing
6.Leroy somer, Stamford, Marathon for you choose
Other Optional part:
Warranty
12 months or 1000 running hours from shipment date. If the quality problem arise during the warranty period,and verified the problem is caused by our genset-body instead of external or natural reasons. (Refer to all kinds of natural disaster, shipping, loading, unloading, wrong-operation, etc), we will supply the relevant spare parts free of charge for maintenance; after the warranty period, we can supply the required spare parts for you under cost prices