With ATS system
As the generator operating, the system will alert and close the generator if the parameter exceed the max, which set by the user. All kinds of altert are as belows:
1. The flood current protection
2. The low voltage protection
3. The high voltage protection
4. The low frequency protection
5. The low voltage protection of the battery
6. The high voltage protection of the battery
7. The machinery temperature protection
8. The low oil protection
9. The protection of starting unsuccessfully
10. The protection of stopping unsuccessfully
MODEL AD3800DSE AD6800DSE-B
Rated frequency(HZ) 50 60 50 60
Rated voltage(V) 220/230 240/120 220/230 240/120
Rated current (A) 12.2 13.8/27.5 18.3 20.8/41.7
Rated output power(kVA) 2.0 2.5 5.5 6.0
DC output 12V/8.3A
Power factor 1.0
Phase Single-phase/Three-phase
Dimension(LXWXH)(mm) 830× 520× 40 910× 530× 740
Packing size(LXWXH)(mm) 900× 565× 770 990× 570× 770
Net/Gross weight(kg) 135/143 175/183
Structure model Silent cart type
Engine model HY178FE HY186FE
Engine type Single-cylinder, 4-stroke, air-cooled, direct-injection, diesel engine
Displacement(cc) 296 406
Compression rate 20: 1 19: 1
Rated output/Speed KW (HP)/rpm) 3.7(5.0)/3000 5.7(7.8)/3000
Starting system Recoil/Electric start with battery
Fuel tank capacity(L) 16
Lube capacity(L) 1.1 1.65
Fuel type Diesel0#(summer), diesel-10#(winter)
Lube brand SAE10W30(above CC grade)
Low oil pressure alarm system With