Product Main

Specifications

Specifications
Size: 2000mm x 1000mm, 4400mm x 2200mm, 3200m x 2200mm
Widely used for power transforer, distributor transformer
 
 
PRESS PAPER
 IEC60641-3-1 (P.4.1)standard,and the main index as following
 
Index item
unit
demand
1.thickness tolerance(max.)
%
±10
2.density
g/cm3
1.0-1.2
3.tensile strength(mix.)longitudinal
Mpa
80
4. tensile strength(mix.)traverse
Mpa
40
5. tensile strength(mix.) traverse after folding
Mpa
A B
35 40
6. tensile strength(mix.) longitudinal after folding
Mpa
60
7.moisture content(max.)
%
8
8.ash content(max.)
%
1
9.electric break town strength(mix.)
 
A B
In oil 0.1.mm
 
9 9
0.15-0.25mm
KV/mm
10 10
0.30-0.35mm
10 -
0.40-0.50mm
9 -
10. electric break town strength(mix.)
 
In are after folding
 
A B
0.10-0.15mm
KV/mm
7 7
0.20-0.25mm
8 8
0.30mm
8 -
0.30-0.50mm
7 -
11. electricity conductivity(max.)
 
8
12.PH of water extractives
Ms/m
6-9
 
PRE-COMPRESSED PAPER BOARD (TRANSFORMER PRESS BOARD)
Abide by IEC60641-3-1 (B.3.1)standard,and the main index as following
Index item
unit
data
1.thickness tolerance(max.)
 
 
less than 1.6MM
 
±7.5
±5.0
more than 1.6MM
2.density less than1.6MM
g/cm3
1.00-1.20
more than1.6MM-3.1MM
 
1.10-1.25
1.15-1.30
more than 3.0MM-6.0MM
3.tensile strength(mix.)
Mpa
 
Longitudinal less than1.6MM
 
100
105
110
1.6MM-3.0MM
3.0MM-6.0MM
4.tensile strength(mix.)traverse less than1.6MM
Mpa
75
1.6MM-3.0MM
 
80
85
3.0MM-6.0MM
5.elongation rate(mix.)longitudinal
%
3.0
6.elongation rate(mix.)Traverse
%
4.0
7.thrinkage(max.)longitudinal
%
0.5
Traverse
 
0.7
5.0
Thickness
8.moisture content(max.)
%
6.0
9.ash content(max.)
%
1.0
10.electricity conductivity(max.)
Ms/m
8.0
11.PH of water extractives
 
6.0-9.0
12.electric breakdown strength(mix)
Kv/m
 
In oil :less than1.6MM
 
40
35
30
1.6MM-3.0MM
3.0MM-6.0MM