Model: YH3001FEATURES
Earth resistance clamp is a breakthrough from traditional tester. Neither the supplementary earth leads nor the break earth equipment is necessary. Ground resistance result can be safe and fast only by clamping the ground line.
Additionally, current testing is also provided. High sensitivity clamp meter can measure the leakage current to 1mA, neutral current to 30A RMS. It is especially important for testing ground circuit with strong interferecnce and ripple that will influence the electrical quality.
Besides industrial electronic equipment. It is also widely used in the field of electric power distribution, telecommunication and architectural ground.
1, 0.01Ω high accuracy for low resistance measurement
2, 0.001Ω high resolution
3, Record 99 resistance measurement values
4, Set alarm threshold in 1Ω to 100Ω
5, Measure leakage current and neutral current
6, 45mm x 32mm large jaws of exactitude measurement probe
7, Indication of the batteries capacity
8, Digital measurement, autorange, easy operation
9, Double insulation, strengthen the interference resistance
10, Untouched measurement, ensure the safety
One second pe SPECIFICATIONS
|
Range
|
Accuracy
|
Resolution
|
Resistance
|
0.01Ω to 0.999Ω
1Ω ~ 9.99Ω 10Ω ~ 99.9Ω 100Ω ~ 199.9Ω 200Ω ~ 400Ω 400Ω ~ 500Ω 500Ω ~ 1000Ω |
±(1.5% + 0.01Ω)
±(1.5% + 0.1Ω) ±(2.0% + 0.3Ω) ±(3.0% + 1Ω) ±(6.0% + 5Ω) ±(10% + 10Ω) approx. 20% |
0.001Ω
0.01Ω 0.1Ω 1Ω 1Ω 1Ω 1Ω |
|
|
|
|
Current
|
100mA
300mA 1A 3A 10A 20A |
±(2.5% + 1mA)
±(2.5% + 2mA) ±(2.5% + 0.003A) ±(2.5% + 0.01A) ±(2.5% + 0.03A) ±(2.5% + 0.05A) |
0.1mA
0.1mA 0.001mA 0.001mA 0.01mA 0.01mA |
11, r test. Imply the quick measurement
12, Display: LCD 3 3/4 digits