12V10A/24V5A UPS Power Supply / Switch Power Supply
High efficiency charge
Cut charging automatically when finish charge
Utility Power and battery switch automatical
High efficiency charge
Cut charging automatically when finish charge
Utility Power and battery switch automatical
Low price and high reliability
AC input power suitable for the world
High efficiency and low operation temperature
Soft-start current can reduce the AC input impact effectively
With Short-circuit and overload protection
100% full-load burning test
Battery low voltage protection
Installed with EMI filter, minimum wave.
2 years warranty
Our goal is to provide right and quality products with most friendly software.
|
Model
Specification |
12V10A UPS
|
24V5A UPS
|
|||||
|
DC output voltage
|
C H 1: 1 3. 8 V
|
C H 2:1 3.4 V
|
C H 1:2 7.6 V
|
C H 2:2 6.5 V
|
|||
|
Output voltage error(Note: 2)
|
± 1%
|
-----
|
± 1%
|
± 1%
|
|||
|
Rated output current
|
8A
|
0.5A
|
4A
|
0.3A
|
|||
|
Output current rage
|
0-8A
|
-----
|
0-4A
|
-----
|
|||
|
Wave and noise(Note : 3)
|
120mVp-p
|
-----
|
180mVp-p
|
-----
|
|||
|
DC output power
|
117.1W
|
118.4W
|
|||||
|
Efficiency
|
84%
|
84 %
|
86%
|
86%
|
|||
|
Adjustable range for DC voltage
|
C H 1:1 1.3~1 4.9 V
|
C H 1:2 1.3~2 9.8 V
|
|||||
|
AC input voltage range
|
88-132VAC/170-264V AC Selected by switch, 47-63Hz: 240-370VDC
|
||||||
|
Input current
|
2.8/115V 1.4A/230A
|
||||||
|
AC Inrush current
|
Cold-start current 30A/115V 50A/230V
|
||||||
|
Leakage current
|
< 1mA/240VAC
|
||||||
|
Overload protection
|
105%-150%Type: Foldback: current limiting reset: auto recovery
|
||||||
|
Battery low voltage protection
|
9.5~11V
|
20~22V
|
|||||
|
UPS function
|
High efficiency charge, Battery can be charged more than 90% full
|
||||||
|
Cut charging automatically when finish charge, protect battery from overcharge
|
|||||||
|
Utility Power and battery switch automatically
|
|||||||
|
Cold start function, battery can start UPS when utility power cut
|
|||||||
|
Temperature coefficient
|
± 0.03%/° C(0-50° C)
|
||||||
|
Setup rise hold up time
|
200ms, 50ms, 20ms
|
||||||
|
Vibration
|
10-500Hz, 2G 10min, /1cycle, Period for60min, Each axes
|
||||||
|
Withstand voltage
|
Input and output internal: 1.5KVAC, Input and enclosure: 1.5KVAC, Output and enclosure:. 5KVAC
|
||||||
|
Isolation resistance
|
Input and output internal: Input and enclosure, Output and enclosure: 500VDC/100MΩ
|
||||||
|
Working temperature and humidity
|
-10° C~+60° C(Refer to output derating curve), 20%~90%RH
|
||||||
|
Store temperature and humidity
|
-20° C~+85° C. 10%~95%RH
|
||||||
|
Overall dimension
|
159× 98× 38mm
|
||||||
|
Weight
|
0.45Kgs
|
||||||
|
Note:
1. The testing condition for the parameter above is : 230VAC input, rated load, 25° C70% RH. Humidity. 2. Error. Include the setting error, line stability and load stability. (Note: 5). 3. Wave test: adopting " A12" double wire for 20MHz, and 0.1UF& 47UF capacitor short-circuit for interrupting. 4. Inlet voltage stability test: when is over load, the lowest voltage of inlet is up to the highest voltage. 5. Load stability test: the load is from 0% to 100%. |
|||||||