Installation
Capacitive level measurement principle: probe line and conductive liquid constituted the
capacitor, among them the metal inner core of probe line is one pole of capacitor the other pole is conductive liquid, the material between them is high stability PPR or gather fluorine ethylene.The probe line insulators outer as media of capacitor poles, the space which surrounden by liquid is changedalong with the liquid level changing, so that make relative space of capacitor polar changed which leading to the changed of capacitance. According to the capacitance formula we can find out the relationship between liquid height and capacitance.
Features
Probe Φ 12 mm, stainless steel 304 thread interface and aluminum shell
Dc single power supply, built-in high-performance special chip
No dynamic elastic parts, high dependability ,Zero and stroke can be adjusted according to customer requirements
This liquid level does not apply to high viscous medium testing, such as the melting asphalt, petrochemical crude oil
Customized according to different detection, can adapt to a variety of demanding conditions of the liquid level detection, more detail information please see our products catalogs
Applications
Chemical plant: dacron, spandex, acid, alkali, and other chemical raw material level detection
Environmental protection: sewage level detection
Hydraulic machinery: lubricating oil detection
Light industry: cooking oil level detection
Specifications
Power supply : 9~28V DC
Stroke range : 200~3000mm
Output signal : 1. 0~5V DC 2. 4~20mA three wires 3.Digital type RS485(ModBus RTU)
Linearity: Analog output-±0.25%, ±0.5%
Medium temperature: -60℃~+180℃
Operating temperature: –25℃~85℃
Capacitive level measurement principle: probe line and conductive liquid constituted the
capacitor, among them the metal inner core of probe line is one pole of capacitor the other pole is conductive liquid, the material between them is high stability PPR or gather fluorine ethylene.The probe line insulators outer as media of capacitor poles, the space which surrounden by liquid is changedalong with the liquid level changing, so that make relative space of capacitor polar changed which leading to the changed of capacitance. According to the capacitance formula we can find out the relationship between liquid height and capacitance.
Features
Probe Φ 12 mm, stainless steel 304 thread interface and aluminum shell
Dc single power supply, built-in high-performance special chip
No dynamic elastic parts, high dependability ,Zero and stroke can be adjusted according to customer requirements
This liquid level does not apply to high viscous medium testing, such as the melting asphalt, petrochemical crude oil
Customized according to different detection, can adapt to a variety of demanding conditions of the liquid level detection, more detail information please see our products catalogs
Applications
Chemical plant: dacron, spandex, acid, alkali, and other chemical raw material level detection
Environmental protection: sewage level detection
Hydraulic machinery: lubricating oil detection
Light industry: cooking oil level detection
Specifications
Power supply : 9~28V DC
Stroke range : 200~3000mm
Output signal : 1. 0~5V DC 2. 4~20mA three wires 3.Digital type RS485(ModBus RTU)
Linearity: Analog output-±0.25%, ±0.5%
Medium temperature: -60℃~+180℃
Operating temperature: –25℃~85℃