Electrosurgical Unit /Electrosurgical Instrument
Model: RFS-4000K
Radiofrequency Technology:
High Radiofrequency of 1.5-4.5MHz
The best device and the most advanced technology for high-frequency electrosurgical unit.
It is the first Radiofrequency (1.5-4.5 MHz) surgical instrument in China, which is different from traditional high-frequency electrotome (300-500KHz).
There is no further need to debate the virtues of monopolar versus bipolar technology for minor surgery. Electrosurgical Instrument affords surgeons the ability to utilize both monopolar and bipolar modalities, at the frequency scientifically and clinically proven to produce the least amount of lateral heat and tissue alteration.
High Radiofrequency of 1.5-4.5MHz
The best device and the most advanced technology for high-frequency electrosurgical unit.
It is the first Radiofrequency (1.5-4.5 MHz) surgical instrument in China, which is different from traditional high-frequency electrotome (300-500KHz).
There is no further need to debate the virtues of monopolar versus bipolar technology for minor surgery. Electrosurgical Instrument affords surgeons the ability to utilize both monopolar and bipolar modalities, at the frequency scientifically and clinically proven to produce the least amount of lateral heat and tissue alteration.
Main Specifications:
Electrosurgical Instrument(220 240 volts)
Mode: Cut, Cut & Coag, Coag, Fulguration, Bipolar.
Output Voltage: Variable from 500 to 600 ± 20%
Output Power: 0~100w
Output Frequency: Monopolar mode - 4.00MHz.
Bipolar mode - 1.71 MHz.
Mode & Output Waveform:Cut (Fully Filtered)
Cut & Coag (Fully Rectified)
Coag (Partially Rectified)
Fulguration (Spark-Gap)
Bipolar
Electrosurgical Instrument(220 240 volts)
Mode: Cut, Cut & Coag, Coag, Fulguration, Bipolar.
Output Voltage: Variable from 500 to 600 ± 20%
Output Power: 0~100w
Output Frequency: Monopolar mode - 4.00MHz.
Bipolar mode - 1.71 MHz.
Mode & Output Waveform:Cut (Fully Filtered)
Cut & Coag (Fully Rectified)
Coag (Partially Rectified)
Fulguration (Spark-Gap)
Bipolar
Accessories:
Footswitches
RF Surgipens
Neutral Plates
Surgical Electrodes
Bipolar Forcep
Electrosurgical Instrument Application Area:
1. Dermatology
2. Oculoplastics
3. Oral/Maxillofacial Surgery
4. Otorhinolaryngology
1. Dermatology
2. Oculoplastics
3. Oral/Maxillofacial Surgery
4. Otorhinolaryngology
This technology goes beyond the laser and beyond bipolar in terms of tissue preservation and safety, all at a very affordable price---Electrosurgical Instrument