Control valve of full-automatic water softener
Debugging work of full-automatic water softener control valve:
1. When the full-automatic water softener control vale/fleck controller works, stop the water flowing, open the valve and release the gas of tank, then close the valve.
2. Regulate full-automatic water softener control valve/fleck controller to the backwash, then let the water flow pass for 3-4 min.
3. Open end cover of full-automatic water softener control valve/fleck controller, guarantee that the salt amount and manufacturer are in same, or according to the needed salt content and have the regulation.
4. Regulate the full-automatic water softener control valve/fleck controller to the salt-suction status, until the salt-suction stop.
5. Plug in full-automatic water softener control valve/fleck controller, and check the electromotor whether works or not.
6. Preset the regeneration time of full-automatic water softener control valve/fleck controller.
A. Time type: through the pulling and returning the blade of leaping impeller, rotating the red indicator clockwise(one blade is one day, the red indicator is the current day), we can preset the needed reduction time; regeneration time of full-automatic water softener control valve/fleck controller will start at 2a.m. in the next morning.
B. Flow type delay regeneration: the white point of rotating program gear should aim at the instruction of panel, press this gear, turn the flow meter outwards, make the relative program rotate, turn preset the flow value on the flow meter and align at the white point on the rotated program, when the output reach the preset outset value, the regeneration will start at next morning 2 a.m.
7. Time setting of full-automatic water softener control valve/fleck controller: press the red button, rotate the 24 hours dial, until the time emerges on the top of arrow.
8. Regulate controller to the salt tank water injection, inject the water into the top of air check valve, then make the controller turn back to the working condition automatically.
9. Add the salt into the salt tank until the salt tank is full.
10. Install the end cover of full-automatic water softener control valve/fleck controller.
11. Make the inlet, outlet and bypass valve in the working condition.