Detailed Product Description
1.Floor/Stop/Door: 6/6/6
2.Speed:1.0m/s
3.Load:1150kg
4.GB7588-2003 Carry out the standard
5.ISO9001:2008 certification
Elevator specifications
The anvantageous performance
1.Floor/Stop/Door: 6/6/6
2.Speed:1.0m/s
3.Load:1150kg
4.GB7588-2003 Carry out the standard
5.ISO9001:2008 certification
Elevator specifications
1.car size inside reference
Car
Net
Size
Inside
|
Capacity load(kg)
|
Width(mm)
|
Depth(mm)
|
Car net area inside
|
This
Is
For
Four
Reference
Only
|
1600
|
1950
|
1750
|
≤3.56 m2
|
||
1250
|
1950
|
1500
|
≤2.90 m2
|
||
1150
|
1600
|
1500
|
≤2.65 m2
|
||
1000
|
1600
|
1400
|
≤2.40 m2
|
||
800
|
1350
|
1400
|
≤2.00 m2
|
||
630
|
1100
|
1400
|
≤1.66 m2
|
||
450
|
1150
|
1100
|
≤1.30 m2
|
2. Passenger elevator type choose on speed 1.0m/s
Rate speed(m/s)
|
capacity load(kg)
|
With machine room
|
No machine room
|
Small machine room
|
1.0
|
320
|
yes
|
yes
|
no
|
1.0
|
450
|
yes
|
yes
|
yes
|
1.0
|
630
|
yes
|
yes
|
yes
|
1.0
|
800
|
yes
|
yes
|
yes
|
1.0
|
1000
|
yes
|
yes
|
yes
|
1.0
|
1150
|
yes
|
yes
|
no
|
1.0
|
1250
|
yes
|
yes
|
yes
|
1.0
|
1350
|
no
|
no
|
yes
|
1.0
|
1600
|
yes
|
yes
|
yes
|
3. Passenger elevator type choose on speed 1.5m/s
Rate speed(m/s)
|
capacity load(kg)
|
With machine room
|
No machine room
|
Small machine room
|
1.5
|
630
|
yes
|
yes
|
yes
|
1.5
|
800
|
yes
|
yes
|
yes
|
1.5
|
1000
|
yes
|
yes
|
yes
|
1.5
|
1150
|
yes
|
yes
|
No
|
1.5
|
1250
|
yes
|
yes
|
yes
|
1.5
|
1350
|
no
|
no
|
yes
|
1.5
|
1600
|
yes
|
no
|
yes
|
4. Passenger elevator type choose on speed 1.75m/s
Rate speed(m/s)
|
capacity load(kg)
|
With machine room
|
No machine room
|
Small machine room
|
1.75
|
630
|
yes
|
yes
|
yes
|
1.75
|
800
|
yes
|
yes
|
yes
|
1.75
|
1000
|
yes
|
yes
|
yes
|
1.75
|
1150
|
yes
|
yes
|
No
|
1.75
|
1250
|
yes
|
yes
|
yes
|
1.75
|
1350
|
no
|
no
|
yes
|
1.75
|
1600
|
yes
|
yes
|
yes
|
5. Passenger elevator type choose on speed 2.0m/s
Rate speed(m/s)
|
capacity load(kg)
|
With machine room
|
No machine room
|
Small machine room
|
2.0
|
800
|
yes
|
no
|
no
|
2.0
|
1000
|
yes
|
no
|
yes
|
2.0
|
1250
|
no
|
no
|
yes
|
2.0
|
1350
|
no
|
no
|
yes
|
2.0
|
1600
|
yes
|
no
|
yes
|
6. Passenger elevator type choose on speed 2.5m/s
Rate speed(m/s)
|
capacity load(kg)
|
With machine room
|
No machine room
|
Small machine room
|
2.5
|
800
|
yes
|
no
|
no
|
2.5
|
1000
|
yes
|
no
|
yes
|
2.5
|
1250
|
no
|
no
|
yes
|
2.5
|
1350
|
no
|
no
|
yes
|
2.5
|
1600
|
yes
|
no
|
yes
|
The anvantageous performance
1.Precision leveling and high efficiency moving
32-bit microprocessor chip,information processing speed,can be detected an any time the exact location of car to ensure the error is almost zero,while the accuracy of leveling improve operational efficiency.
2.Ldeal riding comfort
Multi-joint control computer can be pre-calculated deceleration distance,pre-set operating curves,high quality vector inverter drive,run the almost perfect comfort.
3.High reliability
Integration with microelectronics 32-bit industrial microprocessor,compact,powerful anti-jamming design to control the system from environmental interference and influence,low failure rate and high reliability.
4.Preventive maintenance
Built-in remote monitoring and control system interface,can lift remote monitoring,diagnostics and data transmission,and has a fault diagnosis and fault storage function,truly from time to for the need for new security concept of peace keeping.
Functions List of Elevator
- with/without drive operation
- Automatic return to the base landing
- Automatic landing
- Call cancel when begin reverse-running
- Cage door opening when elevator arrives the floor where there is a hall call
- Door opening / closing call indication
- Indication in the cage when hall calling
- Self-Learning of shaft data
- Full load non-stop operation
- Overload alarm, Car Operating panel display: “OL”
- Alarming device
- In-car and m/r inter talk device
- Light and fan auto-control
- Elevator Locking Device
- Door closing time auto delaying
- False-call canceling
- Emergency Light
- Driven over current protection
- Door opening / closing time-limited protection
- Rope sliding protection
- Door Nudging
- Trouble self-diagnosis and memory
- Over speed falling protection
- Top/Bottom landing overpass protection
- Inspection Operation
- Floor display
- Light curtain protection with mechanical safety edge
- Fireman’s return switch