Product Main

Specifications

Main Features
  Intelligent full digital controlled design
  Using full digital controlling technology makes UPS detection, response, protection more accurate and speedy,which greatly upgrade UPS systems reliability.
  Comprehensive function and reliable power protection
  Real time self check and adjustment, strengthen the UPS protection;
  True online double conversion design with isolation transformer, guarantee the high reliability;
  Industrial power supply,galvanic isolation ,resist to cold load pickup, good dynamic response;
  Settable inner parameters and adjustment, more suitable to user environments.
   
  Intelligent battery management system, greatly reduce the input cost
  Intelligent full bridge rectifier& charger with softstart function and the protection of phase dislocation, phase lack,over voltage, under voltage, over current. Achieving battery auto monitoring,maintenance,management, auto transfer between floating charge and quick charge, ensuring battery life time with most reasonable charge mode.
  Real time monitor and adjust charge mode, auto transfer the charge mode and features with charging current compensation, auto adjust charging current;
  Periodic test and calculate the battery capacity, tell the battery backup time,send the fault messages in time for each battery fault;
  Battery wrong connection and voltage abnormal protection;
  Compatible with various generators, cutting down the UPS running cost.
  Monitoring and network management upgrade the UPS power protection
  RS232 port and SNMP card make UPS possible to realize monitoring and network communications,Monitoring operation can also be achieved by using dry contact.
  Humanization design of UPS structure, more closer to users
  Easy to maintain and simple to install;
  Intelligent cooling fan thermal solution;
  4×12 characters LCD backlight display, more than 200 messages of events, data and history.
  Specification
 
   
Model  
Capacity VA/Watts: RP100L33/8KW,RP150L33/12KW,
RP200L33/16KW, RP300L33/24KW, RP400L33/32KW (Long Run UPS w/o battery,parallel redundancy)
Rectifier  
Phase: Three Phase input/three phase output
Input: 3×380Vac+N+W
Voltage range: 320~480Vac
Frequency: 45-65 Hz
Inverter features  
Voltage range: 3X380Vac+N+W
Voltage stability: 380±1%(static load); 380±2%(50~0% load change); 380±3%(100~0% load change)
Frequency stability: 50Hz±0.1%
Waveform: Pure sine wave
Distortion: <1%(Full linear load);<3%(100~0%load change)
Power factor: 0.8
Overload: >120% for normal bypass ; >150% for 10 minute bypass or shut down
Crest ratio: 3∶1
Load unbalance: Three phase load 100% unbalance
Voltage unbalance: ≤1% (Balance load); ≤2%(50% unbalance load)
Phase displacement: ≤1° (Balance load); ≤2°(50% unbalance load)
General features  
Efficiency: >92%
Switching time: 0ms
Noise suppressor: <55~65dB(At 1 meter)
Working temperature: -10- 40℃
Environment umidity: <95% Non-condensing
Safety standard: EN50091-1/IEC950
Parallel redundancy: Connect up to 6 units in parallel
EMC standard: EN50091-2
Generator compatible: Yes
Protection: Overload, short circuit, over temperature, mains over/under voltage, Battery over/under voltage
Display: LCD (4X12 in English & Chinese, event log with 112 messages)+LED
DC starts Yes
Battery features  
Type: Maintenance-free sealed lead-acid
Floating Voltage: 405Vdc
Battery Voltage: 360Vdc (32Pcs 12Vdc)
Bypass  
Static bypass input: 380 Vac±15%
Static bypass ransfer: 0ms
Frequency tracking rate: 1Hz/sec or 5Hz/sec (optional)
Frequency range: ±2%, 4%, 6%(optional)
Static bypass overload: 200%~5 minutes; 1000%~10 seconds
Manual Bypass: Yes
Communication terface
Comconnect: True RS-232 communication port, Dry contact/RS485/SNMP card
Monitor software: Various operating systems supported
Physical parameter
Dimension(WxDxH): 430X1030X985
Weight (Kg): RP100L33/217,RP150L33/230,RP200L33/250, RP300L33/288,RP400L33/340