Main Features |
|
Leading control technology |
|
Utilize multi CPU+CPLD control technology, make UPS high intelligent,detection and protection more speedy and accurate, improve the whole UPS performance. |
|
Comprehensive function and reliable power protection |
|
New generation power device with high current density and low loss,high stability and reliability; |
|
Real time self test and ajustment,strengthen the UPS protection; |
|
True online double conversion technology, guarantee the high reliability; |
|
Galvanic isolation,resist to cold load impact, fast response time; |
|
Settable inner parameters , more suitable to user environments. |
|
Intelligent battery care system |
|
Intelligent rectifier/ battery charger with equalizing charge and floating charge auto transfer, quick charge and battery activation, which ensure the battery service life. |
|
N+X parallel redundant operation |
|
Friendly human-machine interface and intelligent monitoring software |
|
320 ×240 dot matrix super LCD display the UPS running status, provide 90 messages and measurements,records and history information. |
|
UPS realize network management and remote monitoring through RS 232 port and SNMP slot, monitoring operation can also be achieved by dry contact. |
|
Intelligent cooling fan thermal solution; |
|
Easy to maintain & optimized structure; |
|
Specification |
|
Model |
|
Capacity VA/Watts: |
RP100L33-K/8KW, RP150L33-K/12KW, RP200L33-K/16KW, RP300L33-K/24KW, RP400L33-K/32KW (Long Run UPS w/o battery,parallel redundancy) |
Rectifier |
|
Phase: |
Three Phase input/three phase output |
Input: |
3×380Vac+N+W |
Voltage range: |
300~460Vac |
Frequency: |
45-65 Hz |
Inverter features |
Voltage range: |
3X380Vac+N+W |
Voltage stability: |
380±1%(static load); 380±3%(100~0% load change) |
Frequency stability: |
50Hz±0.1% |
Waveform: |
Pure sine wave |
Distortion: |
<1%(Full linear load);<3%(100~0%load change) |
Power factor: |
0.8 |
Overload: |
>120% for 10 minute bypass or shut down ;
>150% for 1 minute bypass or shut down |
Crest ratio: |
3∶1 |
Load unbalance: |
Three phase load 100% unbalance |
Voltage unbalance: |
≤1% (Balance load); ≤2%(50% unbalance load) |
Phase displacement: |
≤1° (Balance load); ≤2°(50% unbalance load) |
Freq. Tracking Range: |
45-65 Hz |
General features |
Efficiency: |
>92% |
Switching time: |
0ms |
Noise suppressor: |
<50dB(At 1 meter) |
Working temperature: |
-10- 40℃ |
Environment umidity: |
<95% Non-condensing |
Safety standard: |
EN50091-1/IEC950 |
Parallel redundancy: |
Connect up to 8 units in parallel |
EMC standard: |
EN50091-2 |
Generator compatible: |
Yes |
Protection: |
Overload, short circuit, over temperature, mains over/under voltage, Battery over/under voltage |
Display: |
LCD (320X240 dot matrix in English & Chinese, event log with 90 messages)+LED |
Battery features |
Type: |
Maintenance-free sealed lead-acid |
Floating Voltage: |
438Vdc |
Battery Voltage: |
384Vdc (32Pcs 12Vdc) |
Bypass |
|
Static bypass input: |
380 Vac±15% |
Static bypass ransfer: |
0ms |
Frequency range: |
±5%(±5%, ±2% selectable from front control panel) |
Static bypass erload: |
200%~5 minutes; 1000%~10 seconds |
Manual Bypass: |
Yes |
Communication terface |
Comconnect: |
True RS-232 communication port, Dry contact/RS485/SNMP card |
Monitor software: |
Various operating systems supported |
Physical parameter |
Dimension(WxDxH): |
430X1030X985 |
Weight (Kg): |
RP100L33-K/210, RP150L33-K/224, RP200L33-K/230, RP300L33-K/280, RP400L33-K/330 |
|