  Leading control technology
  Utilize multi CPU+CPLD control technology, make UPS high intelligent,detection and protection more speedy and accurate, improve the whole UPS performance.
  Comprehensive function and reliable power protection
  New generation power device with high current density and low loss,high stability and reliability;
  Real time self test and ajustment,strengthen the UPS protection;
  True online double conversion technology, guarantee the high reliability;
  Galvanic isolation,resist to cold load impact, fast response time;
  Settable inner parameters , more suitable to user environments.
  Intelligent battery care system
  Intelligent rectifier/ battery charger with equalizing charge and floating charge auto transfer, quick charge and battery activation, which ensure the battery service life.
  N+X parallel redundant operation
  Friendly human-machine interface and intelligent monitoring software
  320 ×240 dot matrix super LCD display the UPS running status, provide 90 messages and measurements,records and history information.
  UPS realize network management and remote monitoring through RS 232 port and SNMP slot, monitoring operation can also be achieved by dry contact.
  Intelligent cooling fan thermal solution;
  Easy to maintain & optimized structure;
  Specification
 
Model  
Capacity VA/Watts: RP100L33-K/8KW, RP150L33-K/12KW, RP200L33-K/16KW, RP300L33-K/24KW, RP400L33-K/32KW (Long Run UPS w/o battery,parallel redundancy)
Rectifier  
Phase: Three Phase input/three phase output
Input: 3×380Vac+N+W
Voltage range: 300~460Vac
Frequency: 45-65 Hz
Inverter features
Voltage range: 3X380Vac+N+W
Voltage stability: 380±1%(static load); 380±3%(100~0% load change)
Frequency stability: 50Hz±0.1%
Waveform: Pure sine wave
Distortion: <1%(Full linear load);<3%(100~0%load change)
Power factor: 0.8
Overload: >120% for 10 minute bypass or shut down ;
>150% for 1 minute bypass or shut down
Crest ratio: 3∶1
Load unbalance: Three phase load 100% unbalance
Voltage unbalance: ≤1% (Balance load); ≤2%(50% unbalance load)
Phase displacement: ≤1° (Balance load); ≤2°(50% unbalance load)
Freq. Tracking Range: 45-65 Hz
General features
Efficiency: >92%
Switching time: 0ms
Noise suppressor: <50dB(At 1 meter)
Working temperature: -10- 40℃
Environment umidity: <95% Non-condensing
Safety standard: EN50091-1/IEC950
Parallel redundancy: Connect up to 8 units in parallel
EMC standard: EN50091-2
Generator compatible: Yes
Protection: Overload, short circuit, over temperature, mains over/under voltage, Battery over/under voltage
Display: LCD (320X240 dot matrix in English & Chinese, event log with 90 messages)+LED
Battery features
Type: Maintenance-free sealed lead-acid
Floating Voltage: 438Vdc
Battery Voltage: 384Vdc (32Pcs 12Vdc)
Bypass  
Static bypass input: 380 Vac±15%
Static bypass ransfer: 0ms
Frequency range: ±5%(±5%, ±2% selectable from front control panel)
Static bypass erload: 200%~5 minutes; 1000%~10 seconds
Manual Bypass: Yes
Communication terface
Comconnect: True RS-232 communication port, Dry contact/RS485/SNMP card
Monitor software: Various operating systems supported
Physical parameter
Dimension(WxDxH): 430X1030X985
Weight (Kg): RP100L33-K/210, RP150L33-K/224, RP200L33-K/230, RP300L33-K/280, RP400L33-K/330