S- Beam Load Cell (50Kg~50t)
The AR800-beam load cell is designed forindustrial scale conversion and a variety of process applications.
- Industrial used; dynamic and static measurement strength sensors.
- Fully welded seal with stainless steel cover for hostile environment applications.
Specifications:
- Industrial used; dynamic and static measurement strength sensors.
- Fully welded seal with stainless steel cover for hostile environment applications.
Specifications:
| Technical Data | Unit | |
| Rated Capacity | kg | 50,100,200,500 |
| t | 1,2,5,10,20,50 | |
| Rated Output | mV/V | 2.0 |
| Zero Balance | mV/V | 0±0.1 |
| Comprehensive precision | % | 0.2 |
| Temperature Effect On Zero | %/10K | ±0.05 |
| Non-Linearity | % | ±0.05 |
| Hysteresis Error | % | ±0.05 |
| Creep/30 Min | % | ±0.05 |
| Input Resistance | Ω | 400±10 |
| Output Resistance | Ω | 352±2 |
| Reference Excitation Voltage | V | 10 |
| Maximum Excitation Voltage | V | 15 |
| Insulation Resistance | GΩ/100V | >2 |
| Nominal Temperature Range | ℃ | -10~+40 |
| Operating Temperature Range | ℃ | -20~+50 |
| Storage Temperature Range | ℃ | -30~+70 |
| Safe Load Limit | % | 150 |
| Breaking Load | % | 200 |
| Material | Alloy steel | |
| Protection class | IP66 |
Dimension-mm
| Max. cap.[t] | ∅A-0.2 | B | ∅G | H | J | R | ∅SH8 | T | ∅U | X | Y |
| 0.05...1 | 50 | 30 | 42 | 4xM5 | 7 | 60 | 34 | 7 | 13 | 20 | 35 |
| 2 a. 5 | 90 | 48 | 70 | 4xM10 | 12 | 100 | 55 | 12.5 | 25 | 30 | 50 |
| 10 a. 20 | 115 | 60 | 90 | 4xM12 | 16 | 160 | 68 | 12.5 | 32 | 30 | 50 |
| 50 | 155 | 90 | 125 | 4xM16 | 20 | 300 | 97 | 15.5 | 44 | 30 | 50 |