Product Main

Specifications

The PZS5 has the dvanced concrete spraying technique, developed from our PZ series dry-mix shotcrete and incorporated the advantages of wet-mix shotcrete.  Today, it is a universal concrete spraying machine for the processing of wet or dry mix.
 Technical Data:
 
Output
5 M3/h(wet material)
8—9 M3/h(dry material)
Max.convey dist.
35 m
200m
Max.aggregate size
φ15 mm
φ15 mm
Concrete slump
8-15 cm
 
Hose inner size
φ51/65 mm
φ51/65 mm
Operating air pressure
0.2-0.6 MPa
0.2-0.6 MPa
Air consumption
9-10 /min
9-10 /min
Discharge height
1.17 m
1.17 m
Rotor Rev.
11 r/min
11 r/min
Main electric motor power
7.5 kW
7.5 kW
Dosing pupmp model
BRJ15
 Do not need
Dosing pump rated pressure
0.6 MPa
 
Dosing pump output
17.5-88 L/h
 
Overall dimension
2050×950×1180 mm
2050×950×1180 mm
weight
1200 kg
1200 kg
Application:
· Shotcreting for tunnels, hydro-power engineering, mines, underground engineering, civil engineering and slope stabilization, etc.
· Artificial soil seeding for no soil surface, such as rock, sand, and for no fertility soil surface.
· Refractory spraying and repair for industrial kilns or kilns’ inner liner.
 Features:
· Going-through rotor and forced vibrating hopper make mixture smoothly falling.
· Hose dosing pump unit provides constant dosing.
· Thin flow conveying method, used for wet-mix and dry-mix shotcrete.
· Reinforced shotcrete with steel or various polyment fibre. For the most specific risks of this machine, safety and compliance with the essential requirements of the Directive has been based on elements of EN ISO 12100-1:2003, EN ISO 12100-2:2003/A1:1995, EN 60204-1:2006 and EN 1050:1997
 
Drive
Electric (BASIC) 
Motor output : 7.5 KW/10hp 
Speed range : 1500 rpm 
Voltages :  380 V 50 Hz 
440 V 50/60 Hz 
220 V 50 /60Hz
With air motor (AIR)
Motor output: 8kw/11hp
Speed Range: 400-650 rpm
Pressure: 0.63 Mpa/93psi
Air Consumption:  9.4 m³/min
Theoretical conveying date 
Hose Φ (mm) 
Conveying output1) (m3/h) 
max. grain (mm) 
max. conv. dist. (m) Horizontal / Vertical 
BASIC 
AIR 
 
50 
3~5 
15 
Dry: 200 / 70 
Wet: 30/20 
65 
3~5 
20 
 
1) With theoretical filling degree of 100%. If motor with 60 Hz =20% higher conveying capacity 
Theoretical data for air consumption for conveying   
Air consumption (m3/min.) 2) 
Dry spraying 
Wet spraying
60 m 
120 m 
30 m 
11 
12 
15 
 
 
2) Air consumption data are approximate values and are depending on conveying distance. 
CAUTION: For the configuration 
AIR (with air motor) it has to be considered: 