No.
|
Items
|
Criterion
|
|
1
|
Over discharge detect voltage |
2.50 ± 0.08V |
|
2
|
Over discharge recovery voltage |
3.00 ± 0.10V |
|
3
|
Overcharge detect voltage |
4.250 ± 0.025V |
|
4
|
Overcharge recovery voltage |
4.15 ± 0.05V |
|
5
|
Over current detect voltage |
0.10 ± 0.025V |
|
6
|
Current consumed in normal operation |
35uA
|
|
7
|
Current consumed in sleeping mode |
10uA
|
|
8
|
Over current protection |
13A
|
|
9
|
Short circuit protection |
Yes
|
|
10
|
Over current protection time |
120mS
|
|
11
|
Short circuit protection time |
1.4mS
|
|
12
|
D1 start-up voltage |
13.8V ± 2% |
|
13
|
D2 start-up voltage |
14.4V ± 2% |
|
14
|
D3 start-up voltage |
14.6V ± 2% |
|
15
|
D4 start-up voltage |
14.9V ± 2% |
|
16
|
D5 start-up voltage |
15.8V ± 2% |
|
17
|
Charge voltage |
16.8V
|
|
18
|
Breakdown voltage |
Max. 20V |
|
19
|
Interior resistance |
31mΩ
|
|
20
|
Working temperature |
-20 – 55℃ |
|
21
|
Size
|
140 x 66 x 4.2mm |