Product Main

Specifications

No.
Items
Criterion
1

Over discharge detect voltage

2.50 ± 0.08V

2

Over discharge recovery voltage

3.00 ± 0.10V

3

Overcharge detect voltage

4.250 ± 0.025V

4

Overcharge recovery voltage

4.15 ± 0.05V

5

Over current detect voltage

0.10 ± 0.025V

6

Current consumed in normal operation

35uA
7

Current consumed in sleeping mode

10uA
8

Over current protection

13A
9

Short circuit protection

Yes
10

Over current protection time

120mS
11

Short circuit protection time

1.4mS
12

D1 start-up voltage

13.8V ± 2%

13

D2 start-up voltage

14.4V ± 2%

14

D3 start-up voltage

14.6V ± 2%

15

D4 start-up voltage

14.9V ± 2%

16

D5 start-up voltage

15.8V ± 2%

17

Charge voltage

16.8V
18

Breakdown voltage

Max. 20V

19

Interior resistance

31mΩ
20

Working temperature

-20 – 55℃

21
Size

140 x 66 x 4.2mm