TM-Type automatic intermittent lubrication pump is comprised of a mini control unit and a worm-gear reduction mechanism. When power supply is connected, this lubrication system will realize automatic intermittent lubricant replenishment.
According to different ranges of discharge volume, the products are divided into two adjustable specs, one is from 1cm3 /cy to 3cm3 /cy, the other is from 2cm3 /cy to 6cm3 /cy.
Intermittent period is specified as 2, 6, 10, 15, 30, 60 or 120 minutes.
1. Lubrication pump specifications
Model
TM3□□□□
TM6□□□□
Oil discharge volume
1cm3 /cy-3cm3 /cy
2cm3 /cy-6cm3 /cy
Oil discharge pressure
0.2Mpa (Max.)
0.3Mpa (Max.)
Intermittent period
2.4/2, 6/5, 10/12, 15/12.5, 30/25, 60/50, 120/100min 50/60Hz
Outlet diameter
M8 x 1.0 (Ø4 matched pipe)
Reservoir capacity
2.0L
Effective capacity
1.5L
Specifications of mini control unit
Model of lubrication pump
TM32
TM□6
TM□10
TM□15
TM□30
TM□60
TM□120
Model
100V
J205-262
J205-166
J205-754
J205-753
J205-749
J205-748
J205-747
200V
J205-263
J202-346
J202-928
J202-908
J202-907
J205-751
J202-935
Intermittent period (min.)
50Hz
2.4
6
12
15
30
60
120
60Hz
2
5
10
12.5
25
50
100
rpm
50Hz
25
10
5
4
2
1
0.5
60Hz
30
12
6
4.8
2.4
1.2
0.6
Specifications of oil level switch
Type
OLV01 (Floor level ON)
Max. ON/OFF capacity
AC30VA DC25W
Max. ON/OFF current
AC0.33VA DC0.5A
Max. ON/OFF voltage
AC250V DC200V
For example, TM630W indicates that this is a TM-Type lubrication pump whose discharge volume is adjustable from 2 to 6 cm3 /cy, intermittent period is 30 minutes, power voltage is 200/220V, and that it is not equipped with oil level switch.
5. Applicable environmental conditions
Ambient temperature: within the range of 0 to 40ºC
Humidity: 30-95%
Viscosity range: 20-2000mm2/s
ransportation and storage
a. Please clear lubricant away from the reservoir before transportation and storage.
b. Take care when transporting and carrying it, avoid strike or excessive pressure.
c. Store it indoor with ambient temperature between -15ºC and 55ºC. Store it in packing box to prevent dust.
7. Discharge volume adjustment instructions
Discharge volume adjustment
is realized by attaching the E- E-ring
ring to the shaft at the indicated
graduation notch. The difference
between every two neighboring E-ring
notches is 0.5 cm3 /cy.