Treadmill adapter 24V 4A with EN61000,GB9254 FY2404000

Specifications:    
Input  100~240VAC 50~60Hz, Need suitable ac power cord for different areas  
AC inlet: IEC320 C6, C8,C14 and AC power cord Not-separately with adapter are available  
Output  Plug: Standard is 5.5*2.1/5.5*2.5, Other size we will provide as your required  
Cable: 1.2M length  
Output voltage and power, details please see bottom model list  
Packing  Product Dimension 154*60*35mm  
White Box 490g/pc   
Include one AC power cord and a adapter  
Safefy and EMC  Safety standards             
EMC Emission            EMC Immunity
UL60950,CSA C22.2,     PSE/J60950,J55022,J3000.                            
CE/EN55022,EN61000,               FCC part 15      
CB/IEC60950, CCC/GB4943, C-tick/N17653,  
V Eup class B           EK KC/K60950,K00022,K00024                
RoHS:EN2002/95-EC                                        
TUV GS/EN60950,EN60335,EN61558,EN62233.
 
 
Protection Resistance Heat when Tested within 10 minutes after product has been planced in a test chamber maintained at 105℃+/-3℃ for 16 hours. The product shall comply with the requirements of dielectric withstand test. Shall have insulation resistance not less than stated below as measured at 500VDC 10 MEGOHMS Minimum between the input and the output. Input and case together. 10 Megohms minimum.  
Inrush Current Peak inrush current shall be limited 15A for a cold start  
Over currrent Products include current fuse located within inut circuit  
Short Circuit Capable of withstanding continuous short circuit and recover automatically  
Ripple and Noise 25~300mVp-p, 20MHz Bandwidth 10uF Ele. Cap.& 0.1uF Cer. Cap  
Reliability  Electrostatic Discharge  At 150pF: 330Ω, for each point, 10 shots of direct discharge or air discharge. (1MΩ/SHOT), have no malfunction. Direct discharge: ±6kV, Air discharge: ±10kV  
Hi-Pot Test  5mA 3000VAC For 2 second between input and output,input and case. At an alternative potenials 5% higher may be applied for 1 second  
Leakage Current 0.25mA maximum, at nominal AC input voltage and frequency   
Temperature Rise  At 25℃ with the rated input 100-240Vac charged to the primary a rated load, on the secondary, every parts of the case surface rise 65℃ or less.  
MTBF Life 30000 hours in full rated load and operation at 25 ℃  
Insulation Resistance  At 25°C after DC 500V 1min between input plug- DC plug, insulation resistance 100MΩ min)  
Environment Working Temp. ~29 ℃ + 45℃  
Working Humidity  20%-90% RH non-condensing  
Storage Temp.Humidity       ~40 to +75℃ 10~95 RH