Product Main

Specifications

Compact Design, Lower Noise POWER Castle Series Online high frequency UPS 6-10KVA/ 3.1 10-20KVA

 

Introduction:

Power Castle 6K-20Kva, single phase, 3/1phase, is a powerful product range with high adaptability and flexibility. Its cut-edge digital control technology of DSP (Digital Signal Processor), can greatly improve the product performance and system reliability, and deliver a compact integration with higher power density.

 Tailored for AC Grid Environment

Output power factor up to 0.8 – applicable to the tendency of future load evolution, and deliver higher payload capability.

Total power factor up to 90% can minimize the power loss of UPS and utilization cost for user. Active power factor correction (PFC) technology allows the input power factor approaching to 1, dramatically reducing the immunity on utility grid.  Excellent input frequency range makes UPS suitable to different power supply devices, i.e. generator set.

 Flexible Configuration as Demand

 High Scalability: fully meet the customer's demands. Online Intervention: safe and online intervention without any power supply interruption to load.

Emergency Power Off (EPO): UPS can be instantly shut off in case of any emergency.

Parallel Kit: realize the parallel extension and redundancy function, offer more flexibility and safety for user's power supply planning.

 Compact Design, Lower Noise

 With leading control technology and craftsmanship, this UPS can greatly increase the power density and reduce the footprint, therefore save more expensive space in your office environment. Additionally, its lower noise during operation can allow you a more comfort working environment.

 Perfect failure protection and alarm function: provide complete failure protection and clear alarm notification function in case of I/O over-voltage or under-voltage, battery over-charge or under-voltage, overload, and short circuit.

 High Reliability

 Its cut-edge digital control technology of DSP (Digital Signal Processor) can deliver higher quality, performance and reliability and can be suitable to all severe environments. Higher payload and overload capability, better load compatibility, and suitable for various load type. Powerful Interference immunity capability in compliance with EMC requirements of IEC61000-4, deliver your device a clean electric environment.

Large LCD display with much information and for Easy Maintenance

LCD displays input output voltage, current, frequency, battery condition, load percent, watts , VA, working mode and necessary information;

If any important fault, UPS will detect it automatically and display on the LCD, easy maintenance

192VDC and 240vdc convertible via jumpers, Easy use

Auto Control running fan, 4levels, energy saving

The fan speed auto control running as per the load and temperature by 4 levels

Event log function, 100events, easier for maintenances

 Rich Communication and Monitoring Features

Provide RS232 interface and communication cable for local ;remote management and monitoring function.(SNMP), CMC, or AS400 card (dry contact)

 Technical Specification

 

Model

PC06

PC10

PC3110

PC3115

PC3120

Capacity

6KVA/4.8kW

10KVA/8kW

10KVA/8kW

15KVA/12KW

20KVA/16kW

Phase

1/1PHASE, 1wire+N+G

3/1APHASE, 3Wires+N+G

Input  PF

Above0.99

THDi

Less than 6%

Input

voltage

Low transfer

L-N:176 VAC ± 3% @ 100% load;130 VAC ± 3% @ 50% load

Low back

L-N:188 VAC ± 3% @ 100% load, 142 VAC ± 3% @ 50% load

High transfer

L-N:286 VAC ± 3%

High back

L-N:270 VAC ± 3%

Input frequency

40-70hz

Battery

DC voltage

192Vdc or 240Vdc

(INBUILT  OR EXTERNAL)

192Vdc or240Vdc (EXTERNAL)

Charge voltage

220Vdc/275Vdc

Recharging current

4A(L)/1A(S)

4A

Battery type

Lead-acid Maintenance-free battery

Battery quantity

16/20PCS*12VDC

Output

Output PF

0.8

Output voltage

220/230/240Vac +/-1%(static)

Frequency

46~54Hz or 56~64Hz (Line mode)
50/60Hz ± 0.1Hz ( Battery mode)

Output current crest factor

3:1(max)

Wave distortion

Less than 2%(linear load), Less than 4% Non-linear load

Over load

105%<load<125% for 1 mins , 125%<load<150% for30sec

Transfer time

0ms (AC-Battery);

0 ms(bypass-inverter)

Parallel

6PCS(Max.)

Indicator

LCD Panel

UPS status, Load level, Load watt, Load VA, Battery level, Input/Output voltage, output current, Bus voltage, Temp, and warning and fault code and events

Alarm

Battery Mode

Sounding every 4 seconds( can mute)

Low Battery

Sounding every second

Overload

Sounding every second

Fault

Continuously sounding

Management

Smart RS-232/USB

Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7, Linux, Unix, and MAC

Optional

SNMP/AS400

Environment

Operation Humidity

0-90 % RH (non-condensing) @ 0- 40°C

Noise Level

Less than 55dBA @ 1 Meter

Less than 58dBA @ 1 Meter

Physical

Net Weight (KG)

28(L)/65(S)

29(L)/66(S)

36(L)/66(S)

48

48

Gross Weight(KG)

40(L)/77(S)

41(L)/78(S)

48(L)/78(S)

57

57

Dimension/MM

(W*H*D)

260*642*582 / 370*792 *682(Unit/Packing)

290*642*600/

390*810*700

(Unit/Packing)

300*600*742/420*920*720

(Unit/Packing)

                         

Note:”L” means long time model &”S” means standard model with inbuilt battery.