Compact Design, Lower Noise POWER Castle Series Online high frequency UPS 6-10KVA/ 3.1 10-20KVA
Introduction:
Power Castle 6K-20Kva, single phase, 3/1phase, is a powerful product range with high adaptability and flexibility. Its cut-edge digital control technology of DSP (Digital Signal Processor), can greatly improve the product performance and system reliability, and deliver a compact integration with higher power density.
Tailored for AC Grid Environment
Output power factor up to 0.8 – applicable to the tendency of future load evolution, and deliver higher payload capability.
Total power factor up to 90% can minimize the power loss of UPS and utilization cost for user. Active power factor correction (PFC) technology allows the input power factor approaching to 1, dramatically reducing the immunity on utility grid. Excellent input frequency range makes UPS suitable to different power supply devices, i.e. generator set.
Flexible Configuration as Demand
High Scalability: fully meet the customer's demands. Online Intervention: safe and online intervention without any power supply interruption to load.
Emergency Power Off (EPO): UPS can be instantly shut off in case of any emergency.
Parallel Kit: realize the parallel extension and redundancy function, offer more flexibility and safety for user's power supply planning.
Compact Design, Lower Noise
With leading control technology and craftsmanship, this UPS can greatly increase the power density and reduce the footprint, therefore save more expensive space in your office environment. Additionally, its lower noise during operation can allow you a more comfort working environment.
Perfect failure protection and alarm function: provide complete failure protection and clear alarm notification function in case of I/O over-voltage or under-voltage, battery over-charge or under-voltage, overload, and short circuit.
High Reliability
Its cut-edge digital control technology of DSP (Digital Signal Processor) can deliver higher quality, performance and reliability and can be suitable to all severe environments. Higher payload and overload capability, better load compatibility, and suitable for various load type. Powerful Interference immunity capability in compliance with EMC requirements of IEC61000-4, deliver your device a clean electric environment.
Large LCD display with much information and for Easy Maintenance
LCD displays input output voltage, current, frequency, battery condition, load percent, watts , VA, working mode and necessary information;
If any important fault, UPS will detect it automatically and display on the LCD, easy maintenance
192VDC and 240vdc convertible via jumpers, Easy use
Auto Control running fan, 4levels, energy saving
The fan speed auto control running as per the load and temperature by 4 levels
Event log function, 100events, easier for maintenances
Rich Communication and Monitoring Features
Provide RS232 interface and communication cable for local ;remote management and monitoring function.(SNMP), CMC, or AS400 card (dry contact)
Technical Specification
Model |
PC06 |
PC10 |
PC3110 |
PC3115 |
PC3120 |
|||||||
Capacity |
6KVA/4.8kW |
10KVA/8kW |
10KVA/8kW |
15KVA/12KW |
20KVA/16kW |
|||||||
Phase |
1/1PHASE, 1wire+N+G |
3/1APHASE, 3Wires+N+G |
||||||||||
Input PF |
Above0.99 |
|||||||||||
THDi |
Less than 6% |
|||||||||||
Input voltage |
Low transfer |
L-N:176 VAC ± 3% @ 100% load;130 VAC ± 3% @ 50% load |
||||||||||
Low back |
L-N:188 VAC ± 3% @ 100% load, 142 VAC ± 3% @ 50% load |
|||||||||||
High transfer |
L-N:286 VAC ± 3% |
|||||||||||
High back |
L-N:270 VAC ± 3% |
|||||||||||
Input frequency |
40-70hz |
|||||||||||
Battery |
||||||||||||
DC voltage |
192Vdc or 240Vdc (INBUILT OR EXTERNAL) |
192Vdc or240Vdc (EXTERNAL) |
||||||||||
Charge voltage |
220Vdc/275Vdc |
|||||||||||
Recharging current |
4A(L)/1A(S) |
4A |
||||||||||
Battery type |
Lead-acid Maintenance-free battery |
|||||||||||
Battery quantity |
16/20PCS*12VDC |
|||||||||||
Output |
||||||||||||
Output PF |
0.8 |
|||||||||||
Output voltage |
220/230/240Vac +/-1%(static) |
|||||||||||
Frequency |
46~54Hz or 56~64Hz (Line mode) |
|||||||||||
Output current crest factor |
3:1(max) |
|||||||||||
Wave distortion |
Less than 2%(linear load), Less than 4% Non-linear load |
|||||||||||
Over load |
105%<load<125% for 1 mins , 125%<load<150% for30sec |
|||||||||||
Transfer time |
0ms (AC-Battery); |
|||||||||||
0 ms(bypass-inverter) |
||||||||||||
Parallel |
6PCS(Max.) |
|||||||||||
Indicator |
||||||||||||
LCD Panel |
UPS status, Load level, Load watt, Load VA, Battery level, Input/Output voltage, output current, Bus voltage, Temp, and warning and fault code and events |
|||||||||||
Alarm |
||||||||||||
Battery Mode |
Sounding every 4 seconds( can mute) |
|||||||||||
Low Battery |
Sounding every second |
|||||||||||
Overload |
Sounding every second |
|||||||||||
Fault |
Continuously sounding |
|||||||||||
Management |
||||||||||||
Smart RS-232/USB |
Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7, Linux, Unix, and MAC |
|||||||||||
Optional |
SNMP/AS400 |
|||||||||||
Environment |
||||||||||||
Operation Humidity |
0-90 % RH (non-condensing) @ 0- 40°C |
|||||||||||
Noise Level |
Less than 55dBA @ 1 Meter |
Less than 58dBA @ 1 Meter |
||||||||||
Physical |
||||||||||||
Net Weight (KG) |
28(L)/65(S) |
29(L)/66(S) |
36(L)/66(S) |
48 |
48 |
|||||||
Gross Weight(KG) |
40(L)/77(S) |
41(L)/78(S) |
48(L)/78(S) |
57 |
57 |
|||||||
Dimension/MM (W*H*D) |
260*642*582 / 370*792 *682(Unit/Packing) |
290*642*600/ 390*810*700 (Unit/Packing) |
300*600*742/420*920*720 (Unit/Packing) |
|||||||||
Note:”L” means long time model &”S” means standard model with inbuilt battery.