700W - 2100W 1 - 3KVA 220V Online High Frequency UPS, Uninterruptable Power Supply
Back Panel Of Power Supply UPS HP9116C 1-3KVA
Applications:
Servers, Data-center, critical network devices, Sensitive electronic equipment, Telecom…
Technical Specifications of Power Supply UPS HP9116C 1-3KVA
Model |
HP9116C 1-3KVA |
||||||
1KT |
1KT-XL |
2KT |
2KT-XL |
3KT |
3KT-XL |
||
Rated Power |
1KVA/700 W |
2KVA/1400 W |
3KVA/2100 W |
||||
Rated Voltage |
220/230/240VAC |
||||||
Rated Frequency |
50/60 Hz |
||||||
Input |
|||||||
Voltage Range |
115~295VAC(±3VAC) |
||||||
Frequency Range |
50HZ:(46~54HZ);60HZ;(56HZ~64HZ) |
||||||
Power Factor |
>0.98 |
||||||
Output |
|||||||
Voltage Regulation |
220/230/240X (1±2%)VAC |
||||||
Frequency Regulation |
50/60Hz ±0.05Hz |
||||||
Power factor |
0.7/0.8(Optional) Standard 0.7 |
||||||
Voltage distortion |
Linear load<3% Non-linear load<6% |
||||||
Overload |
110%~150% for 30s change to bypass model, Recover after load normal |
||||||
Current Crest Ratio |
3:1 max. |
||||||
Transfer time |
0ms(AC mode →Battery mode) |
||||||
Battery |
|||||||
DC Voltage |
36VDC |
96VDC |
96VDC |
||||
Recharge Time |
7hrs to 90% of capacity after full load discharge |
||||||
Recharge Current |
1A |
4A/8A(Optional) |
1A |
4A/8A(Optional) |
1A |
4A/8A(Optional) |
|
Display |
|||||||
LCD |
Display input/output Voltage, Frequency, Battery voltage, Battery capacity, Loading rate. |
||||||
Communication |
|||||||
Interface |
Smart RS232, SNMP (Optional) , USB(Optional) |
||||||
Environment |
|||||||
Operation Temperature |
0~40℃ |
||||||
Humidity |
0~95% non-condensing |
||||||
Storage Temperature |
-25℃~55℃ |
||||||
Sea level elevation |
<1500 m |
||||||
Noise Level(1m) |
<45dB |
<50dB |
<50dB |
||||
Physical Characteristic |
|||||||
Weight(KG) |
N.W. |
14 |
7 |
31 |
13.5 |
31.5 |
14 |
G.W. |
16 |
9 |
33 |
16 |
33.5 |
16.5 |
|
Dimensions: ( W x D x H )mm |
400X145X220 |
460 X192 X340 |
460 X192 X340 |
Key Features
●Large blue black light LCD for detailed real-time UPS status display.
●Pure high frequency online UPS with voltage regulator circuit, which can provide a perfect power protection when UPS working in a poor surroundings.
●Large blue black light LCD for detailed real-time UPS status display.
●Comprehensive Electrical isolation and bypass protection.
●Input PF correction, reduce the harm of harmonic wave to the power grid, it’s convenient to connect mini type generator.
●Automatic alarm; Self-testing function.
●Wide Input voltage range.
Input N/L Inspection function and date line protection.
●DC start when power off, convenient and reliable; Restart automatically when Electricity is restored.
Follow standard of GB/IEC regulation: EMC:GB7260.2/IEC62040-2 GB/17626.2~5/IEC61000-4-2~5 SAFETY:GB4943
Note: Product specifications are subject to change without further notice