SNMP card, USB High Frequency online UPS with 1KVA / 900W, 2KVA / 1800 W, 3KVA / 2700 W
Application
IT and network environment, servers and network devices, telecom, VoIP and security systems, medical systems, diagnosis and medical screening system, Patient record archives, Manufacturing systems, Chip fabrication, Pharmaceutical production, Chemical processing
Technical Specifications of Online UPS HP9117C 1-3KVA
Model |
HP9117 1-3KT/1-3KR |
||||||||||||||||
1KT/1KR |
1KT-XL/1KR-XL |
2KT/2KR |
2KT-XL/2KR-XL |
3KT/3KR |
3KT-XL/3KR-XL |
||||||||||||
Capacity |
1KVA/900 W |
2KVA/1800 W |
3KVA/2700 W |
||||||||||||||
Nominal Voltage |
100/110/120/127VAC or 200/208/220/230/240VAC |
||||||||||||||||
Nominal Frequency |
50/60 Hz |
||||||||||||||||
Input |
|||||||||||||||||
Voltage Range |
60-138VAC or 115-276VAC |
||||||||||||||||
Frequency Range |
50HZ:(46~54HZ); 60HZ:(56HZ~64HZ) |
||||||||||||||||
Power Factor |
>0.98 |
||||||||||||||||
Output |
|||||||||||||||||
Voltage precision |
100/110/120/127VAC(±2%) or 200/208/220/230/240VAC (±2%) |
||||||||||||||||
Frequency precision |
50Hz/60Hz±0.05Hz |
||||||||||||||||
Power Factor |
0.9 |
||||||||||||||||
Harmonic Distortion |
Linear Load<3% Non-Linear Load<5% |
||||||||||||||||
Overload capacity |
overload(110%~150%)after 30 seconds automatically transfer to bypass, it recover after normal load |
||||||||||||||||
Current Crest Ratio |
3∶1 |
||||||||||||||||
Transfer time |
0ms(AC→DC) |
||||||||||||||||
Battery |
|||||||||||||||||
DC voltage |
36VDC |
96VDC |
96VDC |
||||||||||||||
Recharge time |
7 hours to 90% |
||||||||||||||||
Charge Current |
1A |
4A/8A(option) |
1A |
4A/8A(option) |
1A |
4A/8A(option) |
|||||||||||
Panel Display |
|||||||||||||||||
LCD |
UPS status, input/output voltage frequency, battery voltage, capacity, load, temperature, history records |
||||||||||||||||
Language |
English, French, German, Russian, Spanish |
||||||||||||||||
Communicate |
|||||||||||||||||
Communicate interface |
Optional: SNMP card, AS400 card or the CMC provide software, EPO (USB port) |
||||||||||||||||
Working Environment |
|||||||||||||||||
Temperature |
0~40℃ |
||||||||||||||||
Relative humidity |
0~95% non-condensing |
||||||||||||||||
Storage Temperature |
-25℃~55℃ |
||||||||||||||||
Elevation |
<1500 meter |
||||||||||||||||
Noise Level( 1meter) |
<45dB |
<45dB |
<50dB |
||||||||||||||
Physics Characteristic |
|||||||||||||||||
Net weigh(Kg) |
15 |
16 |
8.5 |
9 |
33 |
10.5 |
16.5 |
11.5 |
34 |
11.5 |
17 |
12.5 |
|||||
Gross weight (Kg) |
17.5 |
17.5 |
11 |
11.5 |
35 |
12.5 |
18.5 |
13.5 |
36 |
13.5 |
19 |
14.5 |
|||||
Dimension (WXDXH) |
|||||||||||||||||
Main unit(Tower) |
200X400X145 |
340X460X192 |
340X460X192 |
||||||||||||||
Main unit (Rack mount) |
438X415X80 |
455 X440 X90 |
Follow standard of GB/IEC regulation: EMC:GB7260.2/IEC62040-2 GB/17626.2~5/IEC61000-4-2~5 SAFETY:GB4943
Note: Product specifications are subject to change without further notice
Key Features
● Protects against downtime, data loss and process interruption by providing continuous, clean power
● Offers premium performance with a 0.9 power factor and >95% efficiency
● Increases battery service life and system uptime with ABM battery charging technology
● Enables prolonged runtime of essential equipment during power outages by allowing for orderly, remote shutdown of non-critical systems or processes thanks to a capability to control load segments.
● Provides installation flexibility with a choice of rack or tower designs, both conserving valuable space
● Can replace batteries online, convenient for user to use
● Enhanced monitoring and configuration capability through easily navigated multilingual graphical display.
Replace battery online: ABM Technology: