Auto-diagnose of UPS failure 208/220V/240V Online LF UPS-4-20KVA(2PHASE,3 WIRES)
Introduction:Power Safe (SA)series DSP low frequency UPS is the second generation digital on-line LF UPS .It has been specially designed by HRD UPS to provide perfect uninterrupted power for South America power grid of 110v/120v/127v. A lot of advanced functions and full protections make this UPS to one of the best choice for the 110v, 120vand 127v power grid.
Main Features:
Fully Digital control technology
Online double conversion with PFC
IGBT rectifier and IGBT Inverter & ISO output transformer
Online battery disconnection alarm
Auto-diagnose of UPS failure (easy maintenance)
Input power factor above 0.98
Wide input frequency range 40-70HZ
Flexible network monitoring and management
Large LCD display
Cold start and AC start function
EPO function(Emergency Power Off)
Perfect protections
Technical Specifications:
|
Model |
PSA04H |
PSA06H |
PSA10H |
PSA15H |
PSA20H |
|||
|
Rating capacity |
4KVA/3.2KW |
6KVA/4.8KW |
10KVA/8KW |
15KVA/12KW |
20KVA/16KW |
|||
|
input |
Phase |
2LINES+G |
||||||
|
P.F |
>0.98 |
>0.95 |
||||||
|
Rating voltage |
208/220V/240V |
|||||||
|
Voltage range |
190V/208/220V+/-30% |
|||||||
|
Rating frequency |
60Hz/ 50Hz(auto-sensing) |
|||||||
|
frequency range |
40-70Hz |
|||||||
|
THDi |
<5% |
|||||||
|
Soft start |
0 to 100% , 3 to 5 seconds |
|||||||
|
Charge |
Float charge |
220VDC |
||||||
|
Current |
4 to10A (extendable) |
|||||||
|
Protection |
Charge voltage, over current protection, short circuit protection |
|||||||
|
Battery |
Model |
Lead acid maintenance free battery |
||||||
|
Rating voltage |
192VDC (external), |
|||||||
|
O/P |
P.F. |
0.8(lagging) |
||||||
|
Phase |
2phase 2LINES +N |
|||||||
|
Rating voltage |
120V/208V, 127/240VAC |
|||||||
|
Rating frequency |
50Hz/60Hz(auto sensing) |
|||||||
|
Frequency |
<±0.1Hz in battery mode |
|||||||
|
Voltage |
<±1.5%(static) |
|||||||
|
Crest factor |
3:1 |
|||||||
|
Wave distortion |
Liner load<3%;Nolinear load<5% |
|||||||
|
dynamic load voltage instant distortion |
Liner load<±5%(from 0-50%-100%) |
|||||||
|
Dynamic response recover time |
<40ms |
|||||||
|
overload capacity |
105%~125%10min;125%~150% 1min; >150%10ms |
|||||||
|
transfer time |
0mS(AC-Battery);<4ms(bypass-inverter) |
|||||||
|
System |
display |
LED+LCD |
||||||
|
Efficiency |
100% linear >89% |
|||||||
|
Operate temp |
0~40℃ |
|||||||
|
Humidity |
0~90% (non-condensing) |
|||||||
|
Cooling |
Intelligent fan cooling |
|||||||
|
Noise dB |
<55 (≤1M) |
<60(1M) |
||||||
|
Physics |
configuration |
Tower, IP21 |
||||||
|
Weight (Kg) |
60 |
100 |
128 |
150 |
218 |
|||
|
Dimension (W×H×D)mm |
210×586×563 |
460×950×710 |
||||||