Overload and short circuit protection UPS Smart Power Series Line Interactive 500va -1500va
Ideal Applcation: PC, POS system, small office etc.
- Main Features:
- Micro Controller based intelligent system
- No load shutdown
- Auto charging at both on/off mode
- Inbuilt with AVR
- Overload and short circuit protection
- Pre-Alarm Audio & Visual Signals for Battery low
- Battery deep discharge protection
- User friendly
Specifications:-
|
RATING |
600 VA |
800 VA |
1000 VA |
1200VA |
||||
|
INPUT |
||||||||
|
Voltage Range |
150V AC to 275V AC |
|||||||
|
Frequency |
50Hz +/- 6% |
|||||||
|
OUTPUT |
||||||||
|
Power |
600VA/360W |
800VA/480W |
1000VA/600W |
1200VA/720W |
||||
|
Voltage(Inverter mode) |
220V AC Nominal |
|||||||
|
Frequency(Inverter Mode) |
50Hz +/- 2% |
|||||||
|
Voltage(Mains AVR Mode) |
220V +/- 12% |
|||||||
|
Transfer Time (Typical as) |
3 m.s. |
|||||||
|
PROTECTION |
||||||||
|
Surge Protection |
Optional |
Provided |
||||||
|
Input Fuse |
Provided |
|||||||
|
Modem/Network(OPTIONAL) |
RJ-11 |
RJ-45 |
||||||
|
BATTERY |
||||||||
|
Type |
Sealed Lead Acid Maintenance Free |
|||||||
|
Number |
1 No. 12V 7Ah |
2 No. 12V 7Ah |
2 No. 12V 7Ah |
|||||
|
Typical Recharge Time |
8 Hours (upto 90% of full capacity) |
|||||||
|
Protection |
Deep Discharge Protection |
|||||||
|
Deep Discharge Protection |
User Replaceable |
|||||||
|
PHYSICAL |
||||||||
|
Net Weight(kg.) approx. |
7.0kg. |
13.6 |
14.6 |
|||||
|
Gross Weight (kg) approx. |
7.5kg. |
14.4 |
15.6 |
|||||
|
Dimensions(WxHxD) mm |
95x146x313 mm |
120x196x385 |
120x196x385 |
|||||
|
LED INDICATION |
Inverter On, On Mains Normal, Mains On, Low Battery Trip. |
|||||||
|
COLOUR |
||||||||
|
Mains Normal |
Green |
|||||||
|
On Battery Mode |
Orange |
|||||||
|
Over Load/Batt. Low/Batt. Mode Short-Circuit Trip |
Red |
|||||||
|
No Load Shut Down |
Red Blinking |
|||||||
|
ALARMS |
||||||||
|
On Battery Mode |
Beeps Every 30Sec. |
|||||||
|
Low Battery Pre-alarm |
Continuous Beeping |
|||||||
|
Over Load/Batt. Low/Batt. Mode Short-Circuit Trip |
Inverter mode O/P trip with continuous beeping and low battery indication. |
|||||||
|
Low Battery Pre-alarm |
Continuous Beeping |
|||||||
|
COMPUTER INTERFACE DB9(OPTIONAL) |
Bi-directional (dry contact) Mains failure, |
|||||||
|
|
Low Battery pre-alarm UPS & computer shutdown |
|||||||
|
ENVIRONMENTAL |
||||||||
|
Operating Temperature |
0-40 deg C (32-104 deg F) |
|||||||
|
Storage Temperature |
0-40 deg C (32-104 deg F) |
|||||||
|
Humidity |
0-95% RH non-condensing |
|||||||
Higher capacity models are available on request.
Due to continuous product development specifications are subject to change without prior notice.