Model
|
Function Range
|
Accuracy
|
Controlled Output Object
|
|
RC-210M
|
F01-F12
|
1 ºC
|
Refrigeration, Defrost
|
|
RC-220M
|
F01-F13
|
1 ºC
|
Refrigeration, Defrost
|
|
RC-320M
|
F01-F16
|
1 ºC
|
Refrigeration, Defrost, Fan
|
|
RC-212M
|
F00-F12
|
1 ºC
|
Refrigeration, Defrost
|
|
RC-222M
|
F00-F13
|
1 ºC
|
Refrigeration, Defrost
|
|
RC-312M
|
F00-F16
|
1 ºC
|
Refrigeration, Defrost, Fan
|
|
RC-216M
|
F01-F12
|
0.1 ºC
|
Refrigeration, Defrost
|
|
RC-226M
|
F01-F13
|
0.1 ºC
|
Refrigeration, Defrost
|
|
RC-326M
|
F01-F16
|
0.1 ºC
|
Refrigeration, Defrost, Fan
|
Technical parameters:
Temperature controlling range: -40~110 ºC
Resolution: 0.1 ºC
Power supply: 220VAC±10% 50/60HZ
Consumption: ≤3W
Relay capacity: 5A or 10A
Operating temperature: -10~60 ºC
Operating humidity: 20%~85%
|
Code
|
Function
|
Setting range
|
Default
|
Unit
|
Model
|
|
F00
|
Mode option
|
00:refrigeration 01:heating
|
00
|
/
|
RC-xxxM series
|
|
F01
|
Start up temp.
|
F02~110
|
-8
|
ºC
|
|
|
F02
|
Shut down temp.
|
-40~F01
|
-10
|
ºC
|
|
|
F03
|
Compressor delay
|
0~20
|
3
|
Min.
|
|
|
F04
|
High temp. alarm
|
0~50
|
50
|
ºC
|
|
|
F05
|
Low temp. alarm
|
0~50
|
50
|
ºC
|
|
|
F06
|
Temp calibration
|
-10~10
|
00
|
ºC
|
|
|
F07
|
Defrost cycle
|
0~99
|
6
|
Hr.
|
|
|
F08
|
Defrost time
|
0~99
|
30
|
Min
|
|
|
F09
|
Defrost duration
|
0~20
|
3
|
Min
|
|
|
F10
|
Defrost mode
|
00:electric-heating 01:thermal
|
00
|
/
|
|
|
F11
|
Defrost display
|
00:real–time temp.01:departed temp.
|
00
|
/
|
|
|
F12
|
Forcible refrigeration
|
F02~110
|
30
|
ºC
|
|
|
F13
|
Defrost stop temp.
|
-40~110
|
50
|
ºC
|
|
|
F14
|
Fan mode
|
00:start and stop with compressor simultaneously, close when defrost
01:operation continually, controlled by F13
|
00
|
/
|
|
|
F15
|
Fan stop temp.
|
-40~110
|
10
|
ºC
|
|
|
F16
|
Communication signal
|
000~999
|
000
|
/
|
Suitable for aquarium equipment, air-conditioning, freezer, storage refrigeratory, display freezer, liquor cabinet and other refrigeration equipments. If you’re interested, pls contact me for more details.