Safety/Standard       
       
Physical specifications       

Weight(Standard Configuration)       
Size:300(W)×270(H)×145(D)mm

Display       
Type and size:8.4" Color TFT    
Resolution:800*600    
Number of trace:6 traces    
Sweep speed:12.5mm/s,25mm/s,50mm/s    
Display modes:Standard display    
              Large-font display    
              Trend coexist display    
              OxyCRG dynamic view display    
Drug does calculation:Yes    
Standby mode:Yes 

Opertion Environment       
Temperature:0ºC to 40ºC    
Relative Humidity:≤85% (noncondensing)    
Atmospheric pressure:860hPa~1060 hPa  
Storage/Transportation       
Temperature:-20ºC to 60ºC    
Humidity:≤93%  (noncondensing)    
Atmospheric pressure:860hPa~1060 hPa  

  
Electrical       

Adapter:Input AC 100-240V  50/60Hz 1.7A  Output DC 19V 3A  

Vehicle power supply:DC 12-14V  5A    
AC input power:70VA 

Battery       
Type:Exchangeable Li-ion battery    
Voltage:14.8V    
Maximum number of batteries:2    
Battery life:7 hours with 2 battery    
Charge time (Monitor switched off):4 Hours with 2 battery    
Charge time (Monitor switched on):10Hours with 2battery 

Patient Range:Neonate, pediatric, and adult patients

Alarms       
Categories:Physical alarms and Technical alarms    
Priority:High, Medium, and Low    
Alarm sound levels:0,1,2,3,4    
Notification:Visual and Audible    
Pausing:1min, 2min, 3min    
Setting:Latch, Unlatch    
       
Performance Specifications

Data Storage       
Trend Graph       

Reviewable Parameters:HR,ST,SpO2,PR,NIBP,RR,TEMP    
Resolution:1s, 5s, 5min, 10min    
Trend Data:1 hour short trend at 1s resolution    
           256 hours long trend at 1min resolution 

Trend Table       
Reviewable Parameters:HR,ST,SpO2,PR,NIBP,RR,T1,T2,TD    
Resolution:1,5,10,30,60min    
Trend Data:256 Hours trend date for all parameters    
NIBP measurement:400 Groups       
Reviewable Parameters:ECG,SpO2,NIBP,RESP,TEMP,HR_H>180,HR_L<60,    
                      SpO2<90%, RR_L<10,RR_H>40,    
                      TEMP_H>40ºC,TEMP_L<34ºC   

ECG       
Lead type:3-Lead or 5-Lead selectable    
3 leadwire:I,II, or III    
5 leadwire:I,II, III, V, AVR, AVL, AVF    
Gain:×0.25,×0.5,×1,×2,Auto    
Sweep speed:12.5mm/s, 25mm/s, 50mm/s    
Standardizing voltage:1mV marker    
Bandwidth(Surgery mode):1-20Hz    
Bandwidth(Monitoring mode):0.5-40Hz    
Bandwidth(Diagnostic mode):0.05-130Hz    
Multi-lead display:6 waveforms    
Lead fail:Identifies failed lead    
Alarms:User-selectable upper and lower heart rate limits

ECG derived HR       
Heart Rate for Adult:15-300BPM    
Heart Rate for Neonate/Pediatric:15-350BPM    
Heart Rate Accuracy:±1BPM or ±1%, whichever is greater    
Heart Rate Resulotion:1BPM    
Notch:50Hz, 60Hz

ST Segment       
ST segment range:-2.0mv to 2.0mv    
ST alarm range:-2.0mv to 2.0mv    
ST segment accuracy:-0.8mv to 0.8mv    
ST segment error:±0.02mv    
Arrythmia type:13 types    
ST analysis:2-lead measurement

Pace       
Pace detection:Yes    
Pace rejection amplitude:±2 mV ~ ±700mV    
Pace rejection width:0.1ms ~ 2ms    
Pace rejection rise time:10µs~100µs   

Temperature       
Scale:ºCelsius(C) or ºFahrenheit(F)    
Probe type:YSI typs    
Parameters:T1,T2 and TD    
TD(Temperature difference):Yes    
Measurement range:0~50ºC    
Resolution:0.1ºC    
Accuracy:±0.1ºC    
Refreshing time:approximately 1S    
Nellcor/Masimo OxiMax SpO

SpO2       
Measurement range:1%~100%    
Resolution:1%    
Accuracy:±2%(70%-100%); unspecified(0-69%)    
Alarm range:0~100%

Pulse Rate       
Measurement range:20bpm~300bpm    
Resolution:1bpm    
Accuracy:±3bpm    
Alarm range:0~254bpm

SUNTECH NIBP(non-invasive blood pressure)       
Measurement technique:Oscillometric    
Displayed parameters:Systolic, diastolic and MAP(mean arterial pressure)    
Measurement mode:Manual, Auto,STAT    
Auto cycle time:0-4 Hours    
Measurement unit:mmHg/kPa selectable    
Range of Systolic pressure:Adult:40-270mmHg    
                           Pediatric: 40-200mmHg    
                           Neonate: 40-135mmHg    
Range of mean pressure:Adult:20-235mmHg    
                       Pediatric: 20-165mmH    
                       Neonate: 20-110mmHg    
Range of diastolic pressure:Adult:10-215mmHg    
                   Pediatric: 10-150mmHg    
                   Neonate: 10-100mmHg    
Accuracy:5%    
Resolution:1mmHg    
Alarms:Selectable upper and lower limits    
       for systolic, diastolic and mean pressure    
Over-pressure protection:Double safety protection  

Respiration       
Measurement technique:RA-LL Impedance variation detection    
Range:Adult: 7~120rpm    
      Pediatric/Neonate: 7~150rpm    
Apnea alarm:Yes, 10s,15s,20s,25s,30s,35s,40s selectable    
Sweep speed:6.25mm/s, 12.5mm/s, 25mm/s     
Gain:0.25, 0.5, 1, 2, 4

Recorder       
Type:Thermal dot array    
Vertical resolution:8dot/mm    
Number of waveform channels:2(standard), 1,3(optional)    
Paper width:50mm    
Paper length:13.5m    
Paper speed:25mm/s 

Standard Configuration:ECG,Masimo SPO2,SUNTECH NIBP,TEMP,PR/HR ,Printer,Accessories Bag.\

Optional Functions:Etco2,Wried and Wireless Central Station Systems,  3G Wireless Systems, First Aid Kit. 

ETCO2       
Mainstream CO2       

Measurement range:0-150mmHg    
Accuracy:0 to 40mmHg   ±2mmHg    
         41 to 70mmHg      ± 5% of the reading    
         71 to 100mmHg    ±8% of the reading    
         101 to 150mmHg  ±10% of the reading    
RR range:0 to 150rpm    
Accuracy:1rpm    
Response time:<60ms 

Sidestream CO2       
Measurement range:0-150mmHg    
Accuracy:0 to 40mmHg     ±2mmHg    
         41 to 70mmHg      ± 5% of the reading    
         71 to 100mmHg    ±8% of the reading    
         101 to 150mmHg  ±10% of the reading    
Sample flowerate:50ml/min    
Accuracy:±15% or 15ml/min,whichever is greater    
Warm-up time:<1min,enter the iso accuracy mode     
             After 1 min,enter the full accuracy mode    
RR range:0-120rpm    
RR accuracy:±2 rpm