RC-110E
Technical parameters:
Temperature controlling range: -40~99 ºC
Resolution: 1 ºC
Accuracy: ±1 ºC
Power supply: 220VAC±10%
Consumption: ≤3W
Refrigeration relay capacity: 5A / 10A / 30A (optional)
Other relay: 5A
Operating temperature: -10~60 ºC
Operating humidity: 20%~85%
Code
|
Function
|
Setting range
|
Default
|
Unit
|
Model
|
F0
|
Temp. controlling differential
|
1~16
|
3
|
ºC
|
RC-110E
|
F1
|
Compressor delay
|
0~9
|
3
|
Min
|
|
F2
|
Lower temp. limit
|
-40~setting temp.
|
-20
|
ºC
|
|
F3
|
Upper temp. limit
|
setting temp~99
|
20
|
ºC
|
|
F4
|
Mode option
|
1.refrigeration 2.heating 3.alarm
|
1
|
/
|
|
F5
|
Temp. calibration
|
-12~12
|
0
|
ºC
|
|
F6
|
Communication signal
|
000~999
|
000
|
/
|
RC-210E
Technical parameters:
Temperature controlling range: -40~99 ºC
Resolution: 1 ºC
Accuracy: ±1 ºC
Power supply: 220VAC±10%
Consumption: ≤3W
Refrigeration relay capacity: 5A / 10A / 30A(optional)
Other relay: 5A
Operating temperature: -10~60 ºC
Operating humidity: 20%~85%
Code
|
Function
|
Setting range
|
Default
|
Unit
|
Model
|
F0
|
Temp. controlling differential
|
1~16
|
3
|
ºC
|
RC-210E
|
F1
|
Compressor delay
|
0~9
|
3
|
Min
|
|
F2
|
Lower temp. limit
|
-40~setting temp.
|
-20
|
ºC
|
|
F3
|
Upper temp. limit
|
setting temp~99
|
20
|
ºC
|
|
F4
|
Mode option
|
1.refrigeration 2.heating
|
1
|
/
|
|
F5
|
Temp. calibration
|
-12~12
|
0
|
ºC
|
|
F6
|
High temp. alarm
|
F7~99
|
99
|
ºC
|
|
F7
|
Low temp. alarm
|
-40~F6
|
-40
|
ºC
|
|
F8
|
Communication signal
|
000~999
|
000
|
/
|
RC-211E
Technical parameters:
Temperature controlling range: -40~99 ºC
Resolution: 1 ºC
Accuracy: ±1 ºC
Power supply: 220VAC±10%
Consumption: ≤3W
Refrigeration relay capacity: 5A / 10A / 30A(optional)
Other relay: 5A
Operating temperature: -10~60 ºC
Operating humidity: 20%~85%
Code
|
Function
|
Setting range
|
Default
|
Unit
|
Model
|
F0
|
Temp. controlling differential
|
1~16
|
3
|
ºC
|
RC-211E
|
F1
|
Compressor delay
|
0~9
|
3
|
Min
|
|
F2
|
Lower temp. limit
|
-40~setting temp.
|
-20
|
ºC
|
|
F3
|
Upper temp. limit
|
setting temp~99
|
20
|
ºC
|
|
F4
|
Temp. calibration
|
-12~12
|
0
|
ºC
|
|
F5
|
High temp. alarm
|
F6~99
|
99
|
ºC
|
|
F6
|
Low temp. alarm
|
-40~F5
|
-40
|
ºC
|
|
F7
|
Communication signal
|
000~999
|
000
|
/
|
RC-310E
Technical parameters:
Temperature controlling range: -40~99 ºC
Resolution: 1 ºC
Accuracy: ±1 ºC
Power supply: 220VAC±10%
Consumption: ≤3W
Refrigeration relay capacity: 5A / 10A / 30A(optional)
Other relay: 5A
Operating temperature: -10~60 ºC
Operating humidity: 20%~85%
Code
|
Function
|
Setting range
|
Default
|
Unit
|
Model
|
F0
|
Refrigeration temp. controlling differential
|
1~16
|
3
|
ºC
|
RC-310E
|
F1
|
Heating temp. controlling differential
|
1~16
|
3
|
ºC
|
|
F2
|
Compressor delay
|
0~9
|
3
|
Min
|
|
F3
|
Lower temp. limit
|
-40~setting temp.
|
-20
|
ºC
|
|
F4
|
Upper temp. limit
|
setting temp~99
|
20
|
ºC
|
|
F5
|
Temp. calibration
|
-12~12
|
0
|
ºC
|
|
F6
|
High temp. alarm
|
F7~99
|
99
|
ºC
|
|
F7
|
Low temp. alarm
|
-40~F6
|
-40
|
ºC
|
|
F8
|
Communication signal
|
000~999
|
000
|
/
|
RC-312E
Technical parameters:
Temperature controlling range: -40~99 ºC
Resolution: 1 ºC
Accuracy: ±1 ºC
Power supply: 220VAC±10%
Consumption: ≤3W
Refrigeration relay capacity: 5A / 10A / 30A(optional)
Other relay: 5A
Operating temperature: -10~60 ºC
Operating humidity: 20%~85%
Code
|
Function
|
Setting range
|
Default
|
Unit
|
Model
|
F0
|
Heating stop temp.
|
-40~F1
|
20
|
ºC
|
RC-312E
|
F1
|
Refrigeration stop temp.
|
F0~99
|
20
|
ºC
|
|
F2
|
Heating temp. controlling differential
|
1~16
|
3
|
ºC
|
|
F3
|
Refrigeration temp. controlling differential
|
1~16
|
3
|
ºC
|
|
F4
|
Compressor delay
|
0~9
|
3
|
Min
|
|
F5
|
Lower temp. limit
|
-40~setting temp.
|
-20
|
ºC
|
|
F6
|
Upper temp. limit
|
setting temp.~99
|
20
|
ºC
|
|
F7
|
Temp. calibration
|
-12~12
|
0
|
ºC
|
|
F8
|
High temp. alarm
|
F9~99
|
99
|
ºC
|
|
F9
|
Low temp. alarm
|
-40~F8
|
-40
|
ºC
|
Suitable for aquarium equipment, air-conditioning, freezer, storage refrigeratory, display freezer, liquor cabinet and other refrigeration equipments.
If you’re interested, pls contact me for more details.