Product Main

Specifications

RC-110E
Technical parameters:
Temperature controlling range: -40~99 ºC
Resolution: 1 ºC
Accuracy: ±1 ºC
Power supply: 220VAC±10%
Consumption: ≤3W
Refrigeration relay capacity: 5A / 10A / 30A (optional)
Other relay: 5A
Operating temperature: -10~60 ºC
Operating humidity: 20%~85%
Code
Function
Setting range
Default
Unit
Model
F0
Temp. controlling differential
1~16
3
ºC
RC-110E
 
F1
Compressor delay
0~9
3
Min
F2
Lower temp. limit
-40~setting temp.
-20
ºC
F3
Upper temp. limit
setting temp~99
20
ºC
F4
Mode option
1.refrigeration 2.heating 3.alarm
1
/
F5
Temp. calibration
-12~12
0
ºC
F6
Communication signal
000~999
000
/
 
RC-210E
Technical parameters:
Temperature controlling range: -40~99 ºC
Resolution: 1 ºC
Accuracy: ±1 ºC
Power supply: 220VAC±10%
Consumption: ≤3W
Refrigeration relay capacity: 5A / 10A / 30A(optional)
Other relay: 5A
Operating temperature: -10~60 ºC
Operating humidity: 20%~85%
 
Code
Function
Setting range
Default
Unit
Model
F0
Temp. controlling differential
1~16
3
ºC
RC-210E
F1
Compressor delay
0~9
3
Min
F2
Lower temp. limit
-40~setting temp.
-20
ºC
F3
Upper temp. limit
setting temp~99
20
ºC
F4
Mode option
1.refrigeration 2.heating
1
/
F5
Temp. calibration
-12~12
0
ºC
F6
High temp. alarm
F7~99
99
ºC
F7
Low temp. alarm
-40~F6
-40
ºC
F8
Communication signal
000~999
000
/
 
RC-211E
Technical parameters:
Temperature controlling range: -40~99 ºC
Resolution: 1 ºC
Accuracy: ±1 ºC
Power supply: 220VAC±10%
Consumption: ≤3W
Refrigeration relay capacity: 5A / 10A / 30A(optional)
Other relay: 5A
Operating temperature: -10~60 ºC
Operating humidity: 20%~85%
Code
Function
Setting range
Default
Unit
Model
F0
Temp. controlling differential
1~16
3
ºC
RC-211E
F1
Compressor delay
0~9
3
Min
F2
Lower temp. limit
-40~setting temp.
-20
ºC
F3
Upper temp. limit
setting temp~99
20
ºC
F4
Temp. calibration
-12~12
0
ºC
F5
High temp. alarm
F6~99
99
ºC
F6
Low temp. alarm
-40~F5
-40
ºC
F7
Communication signal
000~999
000
/
 
RC-310E
Technical parameters:
Temperature controlling range: -40~99 ºC
Resolution: 1 ºC
Accuracy: ±1 ºC
Power supply: 220VAC±10%
Consumption: ≤3W
Refrigeration relay capacity: 5A / 10A / 30A(optional)
Other relay: 5A
Operating temperature: -10~60 ºC
Operating humidity: 20%~85%
 
Code
Function
Setting range
Default
Unit
Model
F0
Refrigeration temp. controlling differential
1~16
3
ºC
RC-310E
F1
Heating temp. controlling differential
1~16
3
ºC
F2
Compressor delay
0~9
3
Min
F3
Lower temp. limit
-40~setting temp.
-20
ºC
F4
Upper temp. limit
setting temp~99
20
ºC
F5
Temp. calibration
-12~12
0
ºC
F6
High temp. alarm
F7~99
99
ºC
F7
Low temp. alarm
-40~F6
-40
ºC
F8
Communication signal
000~999
000
/
 
RC-312E
Technical parameters:
Temperature controlling range: -40~99 ºC
Resolution: 1 ºC
Accuracy: ±1 ºC
Power supply: 220VAC±10%
Consumption: ≤3W
Refrigeration relay capacity: 5A / 10A / 30A(optional)
Other relay: 5A
Operating temperature: -10~60 ºC
Operating humidity: 20%~85%
 
Code
Function
Setting range
Default
Unit
Model
F0
Heating stop temp.
-40~F1
20
ºC
RC-312E
 
F1
Refrigeration stop temp.
F0~99
20
ºC
F2
Heating temp. controlling differential
1~16
3
ºC
F3
Refrigeration temp. controlling differential
1~16
3
ºC
F4
Compressor delay
0~9
3
Min
F5
Lower temp. limit
-40~setting temp.
-20
ºC
F6
Upper temp. limit
setting temp.~99
20
ºC
F7
Temp. calibration
-12~12
0
ºC
F8
High temp. alarm
F9~99
99
ºC
F9
Low temp. alarm
-40~F8
-40
ºC

Suitable for aquarium equipment, air-conditioning, freezer, storage refrigeratory, display freezer, liquor cabinet and other refrigeration equipments.
If you’re interested, pls contact me for more details.