soft starter inverter for pump and fan
1. Open-loop vector control
2. Built-in PLC
3. Built-in PID regulator
4. 16-step speed
5. traverse operation
6. Continuous operation function at momentary power failure.
7. Perfect fault protection and auto current limit
8. Positive/negative logic switch input signal for option
9. 43 input terminals and 25 output terminals for option
10. 10 frequency input modes.
11. RS-485 communication port (MODBUS protocol)
12. Autotuning function in the mode of either standby or operation.
Item
|
description
|
|
Input
|
Rated voltage, frequency
|
Single phase,220V,50Hz/60Hz; 3 phase, 380V,50Hz/60Hz
|
Allowed fluctuation
|
Continuous voltage fluctuation:within±10%, instant voltage fluctuation: within -15%10%; voltage imbalance: <3%; frequency fluctuation: within 5%
|
|
Output
|
Voltage
|
Single phase,0220V; 3 phase,0380V
|
Output frequency
|
0400Hz.
|
|
Overload capability
|
150% rated current,2 minutes; 180% rated current,10 seconds
|
|
Control trait
|
Command input mode
|
By LCD keypad, by terminals, by PC through serial communication port.
|
Control mode
|
Open loop vector control, VF control.
|
|
Speed setting method
|
By keypad, by analog, by PC through serial communication port
|
|
Speed setting precision
|
Digital command±0.01%(-10 +40)
analog command±0.1%(25oC±10)
|
|
Speed setting resolution
|
Digital command:0.01Hz; analog command:1/2000 of maximum frequency
|
|
Speed control precision
|
Open loop vector control: ±0.5%; (25±10
|
|
Speed control range
|
Open loop vector control: 1:100
|
|
Torque control response
|
Open loop vector control:<200ms.
|
|
Start torque
|
Open loop vector control:150% of rated torque at 0.5Hz.
|
|
Torque control precision
|
±5%
|
|
Set reference voltage supply output
|
1 port, +10V, 5mA
|
|
Control voltage supply output
|
24V,100mA
|
|
Analogy input
|
2 ports, AI1 voltage: 010V, AI2 current/optional voltage010V/020mA AC.
|
|
Analog meter output
|
2 ports,010V/020mZ DC, current/voltage optional
|
|
Operation command connector input
|
2 ports, FWD: forward operation, REV: reverse operation
|
|
Programmable connector input
|
X1X8, 8 ports, programmable digital signal input terminals, X7 and X8 can accept high-speed pulse signal(3.7KW or below, X1X5, 5 ports, X4 and X5 are high speed input)
|
|
DO frequency signal output
|
1 port, high-frequency signal output(programmable)
|
|
Collector open-loop output
|
Two ports:Y1,Y2. Y2 can be selected as pulse output(3.7KW or below, only Y1 available)
|
|
Programmable relay output
|
1 port RA/RB/RC, contactor capacity: 250V AC/3A or 30V DC/1A
|
|
Serial communication port
|
cRS-485 connector RS485+,RS485-
|
|
4 bits LED display
|
setting frequency, output frequency, output voltage, output current, motor speed, output torque, switch value terminal, programming menu parameters and fault code.
|
|
Five indication lamp
|
Parameter unit, RUN/STOP status, special status, charging status.
|
|
Protection function
|
Protection function
|
Over voltage, under voltage, current limitation, over current, overload of inverter, overload of motor, overheat, overvoltage stallout, load short circuit, phase fault.
|
Protection degree
|
IP20
|
|
Cooling mode
|
Forced air cooling
|
|
Environment
|
Ambient termearture
|
-10,+40
|
Termperature
|
2090% RH(no condensation)
|
|
Storage termperature
|
-20,+70
|
|
Application area
|
indoor(no corrosive odor, dust)
|
|
Installation area
|
Altitude is not more than 1000meter, no dust, no corrosive oder, no direct sunlight.
|
|
Vibration
|
20Hz less than 9.8m/s2(0.2g)
|