Product Main

Specifications

INPUT
Voltage : Jumper selectable  95-132V ac or 190-264V ac
Frequency : 50-60 Hz nominal
Phase : 1
OUTPUT
Voltage: max 90V dc at 207V ac input
Current : continuous 4 A dc
Intermittent 6 A for 10 secs : Resistance 15 ohms minimum
Regulation : +/- 1.5% (see note 1)
Thermal drift : 0.05% per deg. C change in AVR ambient (note 2)
 
TYPICAL SYSTEM RESPONSE
AVR response: 20 ms
Filed current to 90% : 80 ms
Machine Volts to 97% : 300 ms
Exteral voltage adjustment : +/-10% with 1 k ohm 1 watt trimmer (see note 3)
Under Frequency protection:
Set point : 95% Hz
Slope : 170% down to 30 Hz
UNIT POWER DISSIPATION : 10 watts maximum
BUILD UP VOLTAGE : 4 Volts @ AVR terminals
ENVIRONMENTAL
Vibration
20-100 Hz  50mm/sec
100Hz – 2kHz  3.3g
Operating temperature : -40 to +70°C 
Relative Humidity 0-70°C 95% 
Storage temperature : -55 to +80°C 
 
NOTES
1. With 4% engine governing
2. After 10 minutes.
3. Applies to Mod status F onwards. Generator de-rate may
apply. Check with factory.
4. Factory set, semi-sealed, jumper selectable
5. Non condensing.