DESCRIPTION
The model A160XVT is a multi-purpose accelerometers. It combines and integrated high performance sensor chip and advanced circuit technology processing which makes it with very low noise as 100ug(root Hz).
The model A160XVT is a multi-purpose accelerometers. It combines and integrated high performance sensor chip and advanced circuit technology processing which makes it with very low noise as 100ug(root Hz).
FEATURES
- ±1g to ±200g range
- Excellent bias stability (less than 0.05% of full)
- Single power supply
- Low power
- Individually calibrated
- Brown out protected
- Demonstrated high reliability
APPLICATIONS
- Vibration Analysis
- Tilt Measurement
- Machine Control
- Alarm System
- Vibration Monitoring
- Robotics
- Instrumentation
SPECIFICATIONS
|
Units
|
A1602VT
|
A1610VT
|
A1630VT
|
A1650VT
|
A1612VT
|
A1621VT
|
Full scale range
|
g
|
±2g
|
±10g
|
±30g
|
±50g
|
±100g
|
±200g
|
Bandwidth(5%)
|
Hz
|
0 to ≥250
|
0 to ≥1000
|
0 to ≥1000
|
0 to ≥1000
|
0 to ≥1000
|
0 to ≥1000
|
Bandwidth(3dB)
|
Hz
|
0 to ≥800
|
0 to ≥3000
|
0 to ≥3000
|
0 to ≥3000
|
0 to ≥3000
|
0 to ≥3000
|
Resonant frequency
|
kHz
|
1.3
|
2
|
4
|
5.1
|
7.2
|
11
|
Noise spectral density in band
|
μV/√Hz typ.
|
25
|
25
|
25
|
25
|
25
|
25
|
(0 ; 4000Hz)
|
max.
|
27
|
27
|
27
|
27
|
27
|
27
|
Bias calibration
|
mg
|
<10
|
<50
|
<150
|
<250
|
<500
|
<1000
|
One year bias stability@6000g
|
mg typ.(max.)
|
1.5(<5)
|
7.5(<25)
|
22(<75)
|
37.5(<125)
|
75(<250)
|
150(<500)
|
Switch on/off repeatability
|
mg max.
|
<0.15
|
<0.75
|
<1.5
|
<3.8
|
<7.5
|
<15
|
Bias temp. coefficient
|
mg/℃ typ.
|
<0.1
|
<0.5
|
<1.5
|
<2.5
|
<5
|
<10
|
|
mg/℃ max.
|
±0.4
|
±2
|
±6
|
±10
|
±20
|
±40
|
Scale factor sensitivity(K1)
|
mV/g
|
1000±8
|
200±2
|
66.6±1
|
40±1
|
20±1
|
10±1
|
One year scale factor stability
|
ppm typ.(max.)
|
300(<1000)
|
300(<1000)
|
300(<1000)
|
300(<1000)
|
300(<1000)
|
300(<1000)
|
Scale factor temp. coefficient
|
ppm/℃ typ.
|
100
|
100
|
100
|
100
|
100
|
100
|
|
min./max.
|
-50/250
|
-50/250
|
-50/250
|
-50/250
|
-50/250
|
-50/250
|
Input axis misalignment (Kp, Ko)
|
mrad max.
|
<10
|
<10
|
<10
|
<10
|
<10
|
<10
|
|
%max
|
1
|
1
|
1
|
1
|
1
|
1
|
Resolution/Threshold(@1Hz)
|
mg max.
|
<0.1
|
<0.6
|
<1.7
|
<2.8
|
<5.5
|
<11
|
Non linearity
|
% of FS max.
|
<0.8
|
<1
|
<1
|
<1
|
<1
|
<1
|
|
g max.
|
<0.02
|
<0.09
|
<0.27
|
<0.50
|
<1
|
<2
|