Product Main

Specifications

Features of AC/DC Powered Photoelectric Smoke Alarm:
  • 100% Brand New and High quality
  • Weight: 168g
  • Size: 105x105x45mm
  • Color: White
  • Excellent stability and High sensitivity.
  • Alarm test button for easy testing.
  • Alarm Indication: Red LED flash.
  • Designed for the fastest possible installation.
Technical Specification:
  • 110V-240V.
  • Sound Level:>=85dB/m
  • Alarm Current: <=20mA
  • Standby Current: 300μA
  • Operating Temperature: -10°C ~ +50°C
  • Operating Humidity: 95%RH
  • Detecting Area:20 square meter
  • Smoke Sensitivity: 2.36%/FT +/-1.251%/FT OBS.




RECOMMENDED LOCATIONS FOR ALARMS
• Locate the first alarm in the immediate area of the bedrooms but not in the bedrooms. Try to protect the exit path as the bedrooms are usually farthest from the exit. If more than one sleeping area exists, locate additional alarms adjacent to each sleeping area.
• Locate additional alarms in the bedrooms if required.
• Locate additional alarms to protect any stairway as stairways act like chimneys for smoke and heat.
• Locate at least one alarm on every floor level.
• Locate an alarm in every room where electrical appliances are operated (i.e. portable heaters or humidifiers).
• Locate an alarm in every room where someone sleeps with the door closed. The closed door may prevent the alarm from waking the sleeper.
• Smoke, heat, and combustion products rise to the ceiling and spread horizontally. Mounting the smoke alarm on the ceiling in the center of the room places it closest to all points in the room. Ceiling mounting is preferred in ordinary residential construction.
• When mounting an alarm on the ceiling, locate it at a minimum of 4” (10 cm) from the side wall (see Figure 1).
• When mounting the alarm on the wall, it is best to use an inside wall with the top edge of the alarm at a minimum of 4” (10 cm) and a maximum of 12” (30.5 cm) below the ceiling, (see Figure 1).
• Put smoke alarms at both ends of a bedroom hallway or large room if the hallway or room is more than 30 feet (9.1 m) long.
• Install Smoke Alarms on sloped, peaked or cathedral ceilings at or within 3ft (0.9m) of the highest point (measured horizontally). (see Figure 2).

LOCATIONS TO AVOID FOR ALARMS
Alarms must not be located within 3 feet of the following:
• Supply and return registers used for forced air heating and air conditioning.
• Ceiling fans and other high air flow areas.
• Bathrooms which contain a tub or shower.
In general, alarms should not be located:
• In the garage. Products of combustion are present when you start your automobile.
• In an area where the temperature may fall below 40ºF or rise above 100ºF.
• In dusty areas. Dust particles may cause nuisance alarms or failure to alarm.
• In a kitchen or cooking area where  steam and smoke from burning food or toast can cause nuisance alarms.
• Near fluorescent lights. Electronic “noise” may cause nuisance alarms.