Features
Good uniformity and low insertion loss
Low Polarization Dependent Loss
Excellent Environmental Stability
Excellent Mechanical
Stability Telecordia GR-1221 and GR-1209
Components through TLC-Certified,Conform to YD1117-2001
Specifications
1×N PLC Specifications
|
|||||||||||
Port Configuration
|
|
1x2
|
1x4
|
1x8
|
1x16
|
1x24
|
1x32
|
||||
Fiber Type
|
G652, G655, G657(G657 A1), etc.
|
||||||||||
Operating Wavelength (nm)
|
1260~1650
|
||||||||||
Insertion Loss (dB)
|
Typ.
|
3.7
|
7.2
|
10.5
|
13.5
|
16.5
|
20.4
|
||||
Max
|
4.1
|
7.4
|
10.7
|
13.7
|
16.9
|
21
|
|||||
Loss Uniformity (dB)
|
Max
|
0.6
|
0.8
|
0.8
|
1.2
|
1.5
|
2.0
|
||||
Return Loss (dB)
|
Min
|
50
|
50
|
50
|
50
|
50
|
50
|
||||
Polarization Dependent Loss(dB)
|
Max
|
0.2
|
0.2
|
0.3
|
0.3
|
0.3
|
0.4
|
||||
Directivity (dB)
|
Min
|
55
|
55
|
55
|
55
|
55
|
55
|
||||
Wavelength Dependent Loss(dB)
|
Max
|
0.3
|
0.3
|
0.3
|
0.5
|
0.5
|
0.8
|
||||
Temperature Dependent Loss (-40~85 ℃) (dB)
|
Max
|
0.5
|
0.5
|
0.5
|
0.8
|
0.8
|
1
|
||||
Operating Temperature ( ℃)
|
-40~+85
|
||||||||||
Storage Temperature ( ℃)
|
-40~+85
|
||||||||||
Package Size (Steel Tube) (mm)
|
Fan-out
|
60x7x4
|
60x7x4
|
60x7x4
|
60x12/x4
|
80x20x6
|
80x20x6
|
||||
Bare
|
40x4x4
|
40x4x4
|
40x4x4
|
50x7x4
|
50x7x4
|
50x7x4
|
|||||
Module
|
40x4x4
|
40x4x4
|
40x4x4
|
50x7x4
|
50x7x4
|
50x7x4
|
|||||
Chassis
|
40x4x4
|
40x4x4
|
40x4x4
|
50x7x4
|
50x7x4
|
50x7x4
|
|||||
2×N Specifications
|
|||||||||||
Port Configuration
|
|
2x2
|
2x4
|
2x8
|
2x16
|
2x32
|
2x64
|
||||
Fiber Type
|
G652, G655, G657(G657 A1), etc.
|
||||||||||
Operating Wavelength (nm)
|
1260~1650
|
||||||||||
Insertion Loss (dB)
|
Typical
|
3.8
|
7.4
|
10.8
|
14.2
|
17
|
21
|
||||
Max
|
4.2
|
7.8
|
11.2
|
14.8
|
17.9
|
21.5
|
|||||
Loss Uniformity (dB)
|
Max
|
1
|
1.4
|
1.5
|
2
|
2.5
|
2.5
|
||||
Return Loss (dB)
|
Min
|
50
|
50
|
50
|
50
|
50
|
50
|
||||
Polarization Dependent Loss(dB)
|
Max
|
0.2
|
0.2
|
0.4
|
0.4
|
0.4
|
0.5
|
||||
Directivity (dB)
|
Min
|
55
|
55
|
55
|
55
|
55
|
55
|
||||
Wavelength Dependent
Loss(dB)
|
Max
|
0.8
|
0.8
|
0.8
|
0.8
|
0.8
|
1
|
||||
Temperature Dependent Loss (-40~85 ℃) (dB)
|
Max
|
/
|
0.5
|
0.5
|
0.8
|
0.8
|
1
|
||||
Operating Temperature (℃)
|
-40~+85
|
||||||||||
Storage Temperature (℃)
|
-40~+85
|
||||||||||
Package Size (Steel Tube) (mm)
|
Bare
|
/
|
60x7x4
|
80x12x4
|
80x12x4
|
80x20x6
|
/
|
||||
Fan-out
|
/
|
60x7x4
|
60x7x4
|
80x12x4
|
80x20x6
|
/
|
|||||
Plastic box
|
/
|
60x7x4
|
60x7x4
|
80x20x6
|
80x20x6
|
/
|
|||||
Chassis
|
/
|
60x7x4
|
60x7x4
|
80x20x6
|
80x20x6
|
/
|
|||||
Note: The above IL is for the PLC splitters without connectors;
for the PLC splitters with connectors, the above IL should add 0.3dB each. |
|||||||||||
Order information
Type
|
Package size
|
Port
|
Fiber Type
|
Input/output pigtail
|
Fiber length
|
In/out connector
|
PLCS
|
BF=bare fiber
FO=fan-out
PB=plastic box
MB=metal box
|
01X02
01x04
01x08
……
02x16
02x32
02x64
|
0=G652D
1=G657A
C=Customize
|
1=bare fiber
2=900µm
tight buffered
3=2.0mm
Loose tube
4=3.0mm
Loose tube
|
1=1m
2=1.5m
C=Customize
|
0=no connector
1=FC/APC
2=FC/PC
3=SC/APC
4=SC/PC
5=ST/APC
6=ST/PC
7=LC/AP
8=LC/PC
C=customize
|
Applications
Fiber to the point (FTTX)
Fiber to the home (FTTH)
Passive optical networks(PON)
Local area networks (LAN)
Cable television (CATV)