Model
|
FAS1800070-C44
|
FAS2400050-C44
|
FAS4800025-C44
|
|
Output
|
Rated voltage
|
18VDC±5%
|
24VDC±5%
|
48VDC±5%
|
Rated current
|
0.7A
|
0.5A
|
0.25A
|
|
Rated power
|
12.6W
|
|||
Ripple
|
≤180mVp-p (full load)
|
≤240mVp-p(full load)
|
≤480mVp-p(full load)
|
|
Start up, rise, hold
|
Start up time 500ms, rise time 50ms (full load), hold time>5ms(full load) | |||
load regulation
|
18VDC±3%
|
24VDC±3%
|
48VDC±3%
|
|
Transmission speed
|
10M/100M; | |||
connection method
|
Data: 1,2,3,6; Power: 4&5(+), 7&8(-) | |||
Input
|
Rated voltage
|
100~240VAC @47~63Hz
|
||
Voltage range
|
90~264VAC @47~63Hz
|
|||
Max current
|
270mA
|
|||
Efficiency
|
>78% (full load at 230VAC)
|
|||
Surge current
|
< 20A at 230V | |||
Leakage current
|
<0.25mA ( at 264VAC/50Hz ) | |||
protection
|
Withstand voltage
|
Input to output 1.5KVAC/3mA ( 1min@50Hz )
|
||
Lighting voltage
|
Withstand 1KV line to line, 2KV line to ground.
|
|||
Insulation resistance
|
Put 500Vdcvoltage on input and output terminal for 1 minute, test resistance>7MΩ | |||
Over load
|
Enter into hiccup mode when load reach 115~200% of full load, recover after remove. | |||
Environment
|
Work temperature, humidity
|
-10℃ ~ +40℃, 10% ~ 90%RH without Condensation
|
||
Storage
|
-20℃ ~ +65℃, 0% ~ 93%RH without Condensation
|
|||
Vibration
|
amplitude 0.35mm, vibrate 10 circles in direction of X,Y,Z, frequency 10-55Hz | |||
safety
|
Standard
|
UL60950, EN60950-1, EN61000, ANSI C63.4
|
||
EMC
|
Standard
|
EN55022 Class B, EN55024, EN61000-3-2, EN61000-3-3
|
||
Other
|
MTBF
|
Continually work 8 hours per day, life>50,000 hours | ||
Burn in
|
At temperature 40±5℃, humidity 0%~93%, 100Vac~240Vac/50Hz, load: 80%~100% / 2 hours
|
|||
weight
|
95g±15g
|
|||
Packing
|
PE bag + hollow plate + carton box
|
|||
Note
|
1. All parameters NOT specially mentioned are measured at 230VAC input and rated load and 25℃ of ambient temperature. 2. Ripple & Noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. |