| Model | FAS1200100 | ||||||
|
DC Output (O/P) |
DC voltage | 12V | |||||
| Rated current | 1A | ||||||
| Current range | 0~1A | ||||||
| Ripple & Noise (max) | 120mVp-p | ||||||
| Rated power | 12W | ||||||
| Voltage tolerance | ±5.0% | ||||||
| Setup, rising time | 500ms, 50ms at full load | ||||||
| Hold up time | >5ms at full load | ||||||
|
Input (I/P) |
Rated Voltage range | 100~240VAC | |||||
| Frequency range | 47~63Hz | ||||||
| Efficiency (average) | >79.2% (min) | ||||||
| AC current | 0.4A(max) | ||||||
| Leakage current | < 0,25 mA at 250 V | ||||||
| Inrush current | < 60 A at 230 V | ||||||
| Protection | Short circuit type | Hiccup mode , but can't damage for permanent short circiut. | |||||
| Over voltage type | 115~150% rated voltage and Shut off O/P voltage, re-power on to recover | ||||||
| Over load type | 115~200% rated output power and Hiccup model, no damage, automatic recover after removing over load condition | ||||||
| Environment | Working temp | 0 ~+40℃ | |||||
| Working humidity | 20 ~90% RH non-condensing | ||||||
| Storage temp & humidity | -20~+85℃, 10~95% RH | ||||||
| Vibration | EN 61131-2 | ||||||
| Safty & EMC | Standards | design refer to EN60950 | |||||
| Withstand voltage | I/P-O/P: 3KVAC, 5mA, 60S | ||||||
| Isolation resistance | I/P-O/P: 100M ohms/500VDC | ||||||
| EMC | EN55022 Class B | ||||||
| Others | Certification | CE | |||||
| MTBF | 300 Khrs, Mil-HDBK-217F(25℃) | ||||||
| Connection | interchangeable AC plugs, DC jack is customized, such as 5.5x2.1x10mm, 3.5x1.35x10m etc. | ||||||
| Dimension | 70.2*39.7*68.9mm (L*W*H) | ||||||
| Weight | TOD | ||||||
| Mounting | wall-mount type | ||||||
| RoHS compliance | Yes | ||||||
| Warranty Period | 2 year | ||||||
| Note: | 1. All parameters NOT specially mentioned are measured at 230VAC input and rated load and 25℃ of ambient temperature. | ||||||
| 2. Ripple & Noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. | |||||||