Product Main

Specifications



Model
FAS100V-12
FAS100V-24
output
Rated voltage
12VDC
24VDC
load regulation
±5%
Ripple
≤120mVp-p (full load)
≤240mVp-p (full load)
Raged current
8.33A
4.17A
Current range
0~8.33A
0~4.17A
Rated power
100W
Start up, rise, hold
Start up time 500ms, rise time 50ms (full load) , hold time>5ms (full load)
Input
Rated voltage 100~240VAC @47~63Hz
Voltage range 90~264VAC @47~63Hz
Max.current
1.15Arms
Efficiency
87% (full load)
Surge current
< 60A at 230V
Leak current
<0.25mA ( at 250VAC/50Hz )
Protection
Withstand voltage
Input to output 1.5KVAC/5mA  ( 1min@50Hz )
Lighting voltage Line to line: 1KVAC.
Insulation resistance
Put 500Vdcvoltage on input and output terminal for 1 minute, test resistance>7M
Over load Enter into hiccup mode when load reach 115~200% of full load, recover after remove
Environment
Operate temperature
-10~+40℃
Storage temperature
-20℃ ~ +65℃
Vibration
amplitude 0.35mm, vibrate 10 circles in direction of X,Y,Z, frequency 10-55Hz
Safety
Standard
UL60950, EN60950-1, EN61000, ANSI C63.4
EMC
Standard
EN55022 Class B, EN55024, EN61000-3-2, EN61000-3-3
Others
MTBF
Continually work 8 hours per day, life>50,000 hours
Burn in
At temperature 40±5℃, humidity 0%~93%, 100Vac~240Vac/50Hz, load: 80%~100% / 2 hours
Dimension
240*69*44mm (L*W*H)
Weight
1.04Kg
package
Carton(260*85*52mm)
Note