Model
|
FAS024V-12
|
FAS024V-24
|
|
output
|
Rated voltage |
12VDC
|
24VDC
|
load regulation |
±5%
|
||
Ripple
|
≤120mVp-p (full load)
|
≤240mVp-p (full load)
|
|
Raged current |
2A
|
1A
|
|
Current range |
0~2A
|
0~1A
|
|
Rated power |
24W
|
||
Start up, rise, hold
|
Start up time 500ms, rise time 50ms (full load) , hold time>5ms (full load) | ||
Input
|
Rated voltage | 100~240VAC @47~63Hz | |
Voltage range | 90~264VAC @47~63Hz | ||
Max.current
|
350mArms
|
||
Efficiency
|
80% (full load)
|
||
Surge current |
< 40A at 230V
|
||
Leak current |
<0.25mA ( at 250VAC/50Hz )
|
||
Protection
|
Withstand voltage |
Input to output 1.5KVAC/5mA ( 1min@50Hz )
|
|
Lighting voltage |
Line to line: 1KVAC
|
||
Insulation resistance
|
Put 500Vdcvoltage on input and output terminal for 1 minute, test resistance>7M | ||
Over load | Enter into hiccup mode when load reach 115~200% of full load, recover after remove | ||
Environment
|
Operate temperature |
-10~+40℃
|
|
Storage temperature |
-20℃ ~ +65℃
|
||
Vibration
|
amplitude 0.35mm, vibrate 10 circles in direction of X,Y,Z, frequency 10-55Hz | ||
Safety
|
Standard
|
UL60950, EN60950-1, EN61000, ANSI C63.4
|
|
EMC
|
Standard
|
EN55022 Class B, EN55024, EN61000-3-2, EN61000-3-3
|
|
Others
|
MTBF
|
Continually work 8 hours per day, life>50,000 hours | |
Burn in |
At temperature 40±5℃, humidity 0%~93%, 100Vac~240Vac/50Hz, load: 80%~100% / 2 hours
|
||
Dimension
|
178*29*21mm (L*W*H)
|
||
Weight
|
200g
|
||
package
|
Carton(200*35*35mm)
|
||
Note
|
1. All parameters NOT specially mentioned are measured at 230VAC input and rated load and 25℃ of ambient temperature. 2. Ripple & Noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. |