ABSTRACT:
Insulated by rigid or flex tube.Applying to pressure measuring and controlling of Rubber, Chemical fiber, Petro-chemical and other special occasions.
PARAMETERS:
|
Capacity Range:0-1-150MPa
|
Comprehensive Precision:0.1%FS, 0.2%FS, 0.3%FS, 0.5%FS, 1.0%FS
|
Output Signal: 2mV/V; 2.5mV/V; 3.3mV/V; 4~20mA; 0~5V; 1~5V; 0~10V
|
Use Temp Range:-10~200℃-400℃
|
Excitation Voltage: Transducer =10V (6~12)V;Transmitter=24V (9~36)V;Transmitter=15~36V
|
Insulation Resistance: ≥2000MΩ,100VDC
|
Eletric Connection: 6 gilded pin / 5 pin
|
Thread connection:1/2-20UNF or Others
|
EXAMPLE: PT111 - 35M - 01 - C - G - 6 / 18 - J - W
|
||||||||||
PT1
|
11
|
35
|
M
|
01
|
C
|
G
|
6
|
18
|
J
|
W
|
11
|
Models
|
|||||||||
35
|
Capacity(Noted by number)
|
|||||||||
M
|
Pressure Measure ( P=Psi, B=Bar, M=MPa )
|
|||||||||
01
|
Output Signal (01=2mV/V, 02=2.5mV/V, 03=3.3mV/V, 04=4~20mA, 05=1~5V, 06=0~5V, 07=0~10V )
|
|||||||||
C
|
Precision (%FS)(B=0.2, C=0.3,D=0.5, E=1.0 )
|
|||||||||
G
|
Thread Connection (F=M12×1,G=M14×1.5,H=1/2-20, L=M18×1.5,M=M22×1.5, N=M28×1.5, P=G3/4, Q=G3/8 )
|
|||||||||
6
|
Length of Rigid Stem( 2 =2.36“, 60mm,6=6”, 152mm)
|
|||||||||
18
|
Length of Flexible Tube(18=18“, 460mm,blank= none)
|
|||||||||
J
|
Thermcouple option (J, K, E, PT100 )
|
|||||||||
W
|
Electric connection(W=5pin, L=6pin )
|