Genset Technical Data
|
||||
Genset Model
|
HL500GF
|
|||
Manufacturer
|
Shandong Huali Electromechanical Co., Ltd
|
|||
Standby power (KVA/KW)
|
687.5/550
|
|||
Prime Power (KVA/KW)
|
625/500
|
|||
Prime / Standby Current (A)
|
900/990
|
Voltage (V)
|
400/230
|
|
Frequency (HZ)
|
50
|
Power Factor
|
0.8
|
|
Connecting Type
|
3 Phase and 4 Wires
|
Voltage adjustment
|
Automatic Constant voltage system
|
|
Steady-state voltage regulating rate,
|
≤±1.0%
|
Steady-state frequency regulating rate,
|
≤±5%
|
|
Voltage Regulation, Stead State
|
≤±0.5%
|
Frequency Regulation, Stead State
|
≤±0.5%
|
|
Instantaneous voltage regulating rate
|
-15% - +20%
|
Instantaneous frequency regulating rate
|
-10% - +10%
|
|
Voltage stability time
|
≤1S
|
Frequency stability time
|
≤3S
|
|
Voltage setting up range
|
≥5.0%
|
Voltage setting range of drop
|
≤-5.0%
|
|
Frequency drop
|
≤3.0%
|
Connection Type
|
International SAE flexible connection
|
|
Overall Size L×W×H (mm)
|
3585×1530×2100
|
Weight (kg)
|
4745
|
|
Power transmission Mode
|
Manual
|
|||
Waveform distortion
|
Sine wave, waveform distortion < 5%
|
|||
Running Environment
|
Environment Temperature≤40℃, Altitude≤1000m,
Relative Humidity≤60%
|
|||
Standard
|
Meet the National Standard :GB/T2820-2009
|
|||
Diesel Engine
|
||||
Model
|
KTAA19-G6A
|
Output Power (KW)
|
610
|
|
Manufacturer
|
CCEC
|
|||
Engine Structure
|
6 , 4-cycle Turbo
|
|||
Bore and Stroke (mm)
|
159×159
|
Rated RPM min
|
1500
|
|
Displacement, total (L)
|
4.21
|
Governor Type
|
Electronic
|
|
Starting Mode
|
24V DC Starter
|
Cooling Mode
|
Air-cooled
|
|
Fuel Consumption Rate (g/kw h)
|
203
|
Compression ratio
|
13.5:1
|
|
Filtration system
|
The integral replacement engine oil, diesel oil filter and air filter
|
|||
Exhaust system
|
Industrial high performance muffler
|
|||
Alternator
|
||||
Model
|
STAMFORD HCI544FS
|
|||
Manufacturer
|
Wudong
|
|||
Configuration, Exciter Type
|
Brushless and Self-Exciting, Self-Radiator,100% Copper Wire
|
|||
Prime power(KVA)
|
625
|
Prime Power(KW)
|
500
|
|
Protection Grade
|
IP21
|
Insulation Class
|
H
|
|
TIF
|
<50
|
THF
|
<2%
|
|
No-loading voltage adjustment range
|
≥±5%
|
Voltage control mode
|
AVR automatic /
manual
|
|
Voltage recovery time
|
<1S
|
Frequency fluctuation rate
|
≤±0.25%
|
|
Overload capacity and time
|
10%,every 12 hours allow 1 hour
|
|||
Control Panel
|
||||
Model
|
HLK500
|
|||
Control Items
|
Current, Voltage, Frequency, Oil Pressure, Water Temperature, RPM and etc.
Random accessories and After-sale service
|
|||
Random accessories
|
Battery, battery connections, absorber, cushion, inlet and return oil pipe, spare parts boxes, random data
|
|||
Warranty
|
Diesel engine executive manufacturers warranty regulations in foreign countries. Alternator three guarantees of one year or1000 hours, whichever comes first
|
|||
Service mode
|
To guide the installation, commissioning, life-long free time charge service
|