Product Main

Quick Details

Type: Other Home Appliance Parts
Model Number: WKI
Brand Name: Thermal International
Place of Origin: China (Mainland)
RoHS, CE,UL: 20 A 250 V

Specifications

Capillary Water Heater Thermostat with Copper Sensor Details
Type
Electric Water Heater Parts
Place of Origin
Guangdong, China (Mainland)
Brand Name
Thermal International
Model Number
WKI
Certificates
RoHS, CE, UL, CQC
Temperature Range
85 degree-135 degree
Electric Rating
20 A 250 V
Frequency
50/60 Hz
Life Usage
100,000 cycles
Wiring Diagram
Double Poles Single Throw
Material of Capillary/Sensor
Copper
Material of Terminal
Brass
Length of Capillary/Sensor
Approx. 400mm
Reset Type
Manual-Reset
Payment & Shipping Terms:
Minimum Order Quantity:
2000 Piece/Pieces Negotiable for Qty less than MOQ
Port:
Shenzhen, Guangdong
Packaging Details:
Standard: Carton Box Nonstandard: Available
Delivery Time:
Within 20-30 days after receipt of deposit
Payment Terms:
L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability:
200000 Piece/Pieces per Month
Detailed Product Description
1. Thermal Protector
2. Temp: 85-135 deg C
3. Rating: 20A-250V
4. DPST
5. Manual-Reset Thermal Protector for electric water heater
Thermal Protector for Electric Water Heater
The WKI Thermal Protector shown in the picture below is a key part in the electric water heaters. It could be made to control temperature from 85 degree Celsius to 135 degree Celsius. Copper-made capillary/sensor is sensitive to the change of temperature, which responds to the action of switch accurately. The DPST contacts open on temperature rise. Noted it is a Manual-reset Thermal Protector that suits the Electric Water Heater.
Features of Thermal Protector for Electric Water Heater
  1. Comply with the UL, CE, RoHS, CQC, ISO regulation.
  2. Special design made for electric water heater
  3. Temperature-preset type
  4. Manual-reset design
  5. Long life usage
  6. Creep Action Switch
Specifications of Thermal Protector for Electric Water Heater
Temperature Range
85°C ~ 135°C
Length of Capillary
Standard: 400mm
Material of Capillary
Copper
Diameter of Sensing Bulb
3mm
Electric Rating
20A-250VAC
Wiring Diagram
Double Pole Single Throw (DPST)
Material of Terminal
Brass
Size of The Nut
1-M10
Min. Capillary Bend Radius
5mm
Temperature Rate of Change
0.8°C/min
There are other Capillary type Thermal Protectors available for your appliances. We will send you more technical information based on your inquiry, as soon as we get the contact from you.