The automatic regeneration control ways of this equipment can be divided into time type and flow type, there are four configurations for user to be chosen from. Except for automatic regeneration, the controller also has manual regeneration, in order to provide users with convenience, when the water exceeds the fixed quantity. Provided that water softener is used together with water level controller, it must be more economic and secure.
I. Single tank time control type, which is suitable for small change of
water-use, the water-use time is fixed, the place can accept intermittent water supply. It needs more or less 2.5 hours without water when regenerates.
II. Single tank flow control type, which is suitable for large change of water-use, the place can accept the intermittent water supply. It needs about half passed 2 hours without water when regenerates.
III. Dual-tank flow control type/multi-tank flow control type, one use one standby/one standby many use (or same time use for separated regeneration), which is suitable for large quantity of water-use, the place must be provided with water continuously.
IV. Dual-tank flow control type, single controller can control two drinker, they are working at the same time, regenerating in proper sequence, which is suitable for large quantity change of water-use, it needs to be provided with water continuously, it has the optimum performance and competitive price.
Installation instructions:
No need of basis for equipment, but we should pay more attention to the following aspects:
1. It must be installed on the horizontal and fixed ground, there is the drainage ditch or waterspout, drainpipe must be less than 6m and lower than valve body.
2. There should be an individual moistureproof power socket within 1m from equipment.
3. Regeneration salt tank should be installed close to resin tank, which can make the most use of salty liquid. There should be enough salt content in salt tank to ensure the regeneration circle
4. All the inlet and outlet pipelines must have independent supports, the valve body cannot be used for support.
5. At the inlet, pressure meter, filter and air-release valve should be installed, and at the outlet, flow meter should be installed.