Product Main

Specifications

Model  SR882
Suitable for  Split Solar Water Heaters
Working Principle
APPLICATIONS CAPACITY Max.number of collectors:1 Max.number of storage tanks:1 Max.number of relays:3 Max.number of sensors:6 Max.number of application system:1
Technical Data
Dimension:  410mm x350mm x165mm
Power supply: 200V-240V AC or 100V-130V AC, 50-60Hz.  .      
Power consumption:  < 3W 
Accuracy of temperature measuring: ± 2centigrade
Range of collector temperature measuring: -10centigrade -200centigrade
Range of tank temperature measuring: 0centigrade -110centigrade
Suitable power of pump: 2 pumps possible to be connected, power of each pump < 200W. 
Suitable power electrical heating: 1 relay for 1500W (1500w-4000w must be use SR802)
Inputs: 6sensors, 
1pcs*Pt1000 sensor (≤500centigrade) for collector (silicon cable≤280centigrade),
5pcs*NTC10K, B3950 sensor (≤ 135centigrade) for tank, (PVC cable ≤105centigrade), 
Outputs:3 relays, for circulation pumps or 3-way electromagnetic valve 
Ambient temperature:-10centigrade - 50centigrade. 
Water proof grade: IP43.
Voltage 220V,110V is availabe against request, 24V is available for 50 sets above order.
Main Function
 Timing heating
Temperature difference control 1*ΔT
Collector emergency shutdown
Collector cooling function
Collector low temperature protection
Collector frost protection
Tank re-cooling function
Maximum temperature of tank  (1*storage  tank)
C-F  Celsius  and  Fahrenheit  temperature  transferring
RPM speed controlling(1*semiconductor)
Thermal energy measuring
Flow  rate  display
Pump interval function.

Maximum  turnoff  temperature  
(for  solid  fuel  boiler,  return  heating,  heat  transferring  between  tanks)
Minimum  turn-on  temperature  
(for  solid  fuel  boiler,  return  heating,  heating  transferring  between  tanks)
Anti-Legionella function
Temperature controlled hot water circulation pump
Thermostat  function( Independent of system)
High  temperature  by-pass  function(Collector  cooling  down)
Data logging  onto  SD  memory  card
Internet  access
Manual Control (for  3  outputs:R1,P2,H1)
Password setting
Recovery to factory setting
Holiday function
Manual Heating
Temperature query function
Memory Protection
Screen protection
Trouble shooting
Trouble protection
Trouble checking