Following are the details you may want to know about
test recharge batteries BTS-10V3A . MOQ: 1set , Delivery : 10-15days if with stock .
We can make as customer requirement. Pls check the battery tester.
SPECIFICATION of recharge batteries tester 10V3A :
Power supply AC 110V or AC 220V
Current range Charge: 6mA~3ADischarge: 6mA~3A
Current measurement accuracy 0.1% of range
Voltage range Charge: 20mV~10VDischarge: 20mV~10V
Voltage measurement accuracy 0.1% of range
Impedance ≥10m
Power 224W
Max measurement cycles 65535 cycle
Step Time Range (1min~365*24hours)/Step
Data record conditions Timet: (5 ~60000S)
VoltageV: (20mV - 10V)
CurrentI: (6mA-3A)
Record Frequency 1HZ
Product Dimension 245mm (W) x 197mm (D) x 60mm (H)
Net Weight 11.5kg
Shipping Weight 35lbs, 22” x 18” x 10”
FEATURES
Channels Eight independent programmable channels.
Each channel can set different working modes and works independently.
Programs The software (TC5.3) can set various working modes for measuring capacity and cycle life of all types of rechargeable battery cells.
Charge Charge Mode Constant Current Charge, Constant Voltage Charge,
Constant Current and Constant Voltage Charge
End Conditon Voltage, Current, Relative Time, Capacity
Discharge Discharge Mode Constant Current Discharge
End Condition Current, Current, Relative Time, Capacity,
Cycle Loop Measure Range 1~65535 times
Max Steps Per Loop 63
Nested Loop Nested loop FunctionMax Support 3 Layers
Time of each working step 1min≤Single Step Time Range≤365*24 h
Data Output EXCEL, TXT, Graph
Test reports and curves for analysis Different types of curves can be created by software base on use defines. (Voltage-time curve, current-time curve, capacity-voltage curve, loops times-charge/discharge capacity curve, loop times-charge/ discharge efficiency curve, etc.
Forms of curves are created by software. User can easily compare the performance of the batteries tested in channels both visually and statistically.
Complete record of all the events happened in the test. By checking the record, user will easily find these external interferential causes.
Communication Interface Serial Port (RS232)
Protection lPower-down Data Protection
lSetting Protection ConditionSetting Parameter: Low Voltage limit, Upper Voltage limit, Low Current limit, Upper Current limit, Delay Time
Voltage and Current Testing Sample 4-wire connecting
test recharge batteries BTS-10V3A . MOQ: 1set , Delivery : 10-15days if with stock .
We can make as customer requirement. Pls check the battery tester.
SPECIFICATION of recharge batteries tester 10V3A :
Power supply AC 110V or AC 220V
Current range Charge: 6mA~3ADischarge: 6mA~3A
Current measurement accuracy 0.1% of range
Voltage range Charge: 20mV~10VDischarge: 20mV~10V
Voltage measurement accuracy 0.1% of range
Impedance ≥10m
Power 224W
Max measurement cycles 65535 cycle
Step Time Range (1min~365*24hours)/Step
Data record conditions Timet: (5 ~60000S)
VoltageV: (20mV - 10V)
CurrentI: (6mA-3A)
Record Frequency 1HZ
Product Dimension 245mm (W) x 197mm (D) x 60mm (H)
Net Weight 11.5kg
Shipping Weight 35lbs, 22” x 18” x 10”
FEATURES
Channels Eight independent programmable channels.
Each channel can set different working modes and works independently.
Programs The software (TC5.3) can set various working modes for measuring capacity and cycle life of all types of rechargeable battery cells.
Charge Charge Mode Constant Current Charge, Constant Voltage Charge,
Constant Current and Constant Voltage Charge
End Conditon Voltage, Current, Relative Time, Capacity
Discharge Discharge Mode Constant Current Discharge
End Condition Current, Current, Relative Time, Capacity,
Cycle Loop Measure Range 1~65535 times
Max Steps Per Loop 63
Nested Loop Nested loop FunctionMax Support 3 Layers
Time of each working step 1min≤Single Step Time Range≤365*24 h
Data Output EXCEL, TXT, Graph
Test reports and curves for analysis Different types of curves can be created by software base on use defines. (Voltage-time curve, current-time curve, capacity-voltage curve, loops times-charge/discharge capacity curve, loop times-charge/ discharge efficiency curve, etc.
Forms of curves are created by software. User can easily compare the performance of the batteries tested in channels both visually and statistically.
Complete record of all the events happened in the test. By checking the record, user will easily find these external interferential causes.
Communication Interface Serial Port (RS232)
Protection lPower-down Data Protection
lSetting Protection ConditionSetting Parameter: Low Voltage limit, Upper Voltage limit, Low Current limit, Upper Current limit, Delay Time
Voltage and Current Testing Sample 4-wire connecting