Product Main

Specifications

Introduction:
EP12/24 10H-1-2L adopts MCU and special software achieving, intelligent control with five operating modes, featuring small volume and high stability. This product can be widely used in solar DC road lamp, solar yard lamp, lawn lamp, solar lightbox and billbord etc.
 
Performance:
1. 12/24V automatic identification.
2. Extreme accuracy in controlling voltage. Adopting 32-bit processor.
3. Automatic temperature compensation function. Hot-awappable to aid temperature transducer.
4. PWM charging modes with higher efficiency.
5. All-round protection function against overcharging, overdischarging, wrong connection, opencircuit, controller and batteries in over temperture, overvoltage, overload, shortcircuit, reverse charging in night etc.
6. Applying nixie tube work modes in overvoltage and overload instruction. A key operation for convinience and intuition.
7. Intelligent 3-section charging control, to assure batteries of fullness, system will switch to relvant modes according to the woking status.
8. Adopting low-loss, long-life MOSFET tube as main switching devices in controller.
9. Auto-saving function for working mode setting. System and important parameters saved inner chip without losing power. Relevant parameters would be read while booting.System is more reliable to work.
10. Various operating modes for choice, optic control, optic control +time control, common mode, manual mode and advanced mode.
 
Data sheet:

Model
EP12/24 10H-1-2L
Rated voltage (V)
12V/24V AUTO
Rated charging current (A)
10
Rated load current (A)
5(single)
Rated efficiency (W)
120, ×2/24V
No-load loss (mA)
≤20
Charging circuit voltage drop (V)
≤0.2V
Discharging circuit voltage drop (V)
≤0.1V
Forcing charging voltage (V)
14.6, ×2/24V
Equalizing charging voltage (V)
14.2, ×2/24V
Floating charging voltage (V)
13.7, ×2/24V
Overvoltage protection voltage (V)
17, ×2/24V
Overvoltage return voltage (V)
15, ×2/24V
Undervoltage protection voltage (V)
10.8, ×2/24V
Undervoltage return voltage (V)
12.3, ×2/24V
Enviromental over-temperature protection
Over 75℃ over-temperture protection act, restart charging at 65℃
Batteries over-temperature protection
Over 75℃ over-temperture protection start, restart charging at 65℃
Over load/short circuit protection
Over load protection will start after 60s or 20s of 1.25 or1.5 times the rated current; and at above 2 times protection will cut off load
Lines loss compensation voltage (V)
0.2
Temperature compensation
-3mV/℃/2V
Control model
PWM charging model
Working temperature
-20℃~+50℃
Dimensions(L×W×H)(mm)
154×88×25
Working elevation (m)
≤5000(if altitude exceeds 1000m, ratings of operation shall be lowered according to standard GB/3859.2)
Protection degree