Product Main

Specifications

Introduction:
ESI-3KVA series inverter adopts digital intelligent control and complete high-frequency topology featuring stable performance and excellent resitance to jam. It’s output voltage is 110V/60HZ, 220V/50HZ and rated power is 3KVA. This product is widely used in these solar system for telecommunication, traffic, house, island, border defense, countryside, pastoral areas etc. 
 
Performance:
1. Output pure sine wave , small waveform distortion rate.
2. Soft start function and high efficiency.
3. Strong load adaptability and stability.
4. Internal fuse against wrong connection for reliability and safety. 
5. Protection against overcurrent and short-circuit, preventing product from burning.
6. Low voltage protection for battery input, preventing battery from over-discharging.
7. Input side DC and output side AC isolated against electric shock for more safety. 
8. All-round protection and alarm function.
9. Complete high-frequency transform, small volume, light weight.
10. Main phase locked, bypass switch and on-grid are available (compatiable UPS function).
 
Data sheet:

Model  
3000VA off-grid inverter
Series
EISH-24-110-3KW  EISH-36-110-3KW EISH-48-110-3KW
EISH-24-220-3KW  EISH-36-220-1KW EISH-48-220-3KW
Input 
 
24VDC
36VDC
48VDC
Work voltage range
20~30VDC
32~42VDC
40~60VDC
No-load input current
≤1.0A
≤1.0A
≤1.0A
Low voltage alarm range
20.5~21.5VDC
30.5~31.5VDC
40.5~42.5VDC
Low voltage close range
19.5~20.5VDC
29.5~30.5VDC
39~41VDC
High-voltage close range
29.5~31VDC
41.5~42.5VDC
59~62VDC
 
Output protection
 
110VAC/60HZ
220VAC/50HZ
Rated power
3KVA
3KVA
Momentary power
6KVA
6KVA
Output waveform
Pure sine wave
Pure sine wave
Distoration rate
≤3%
≤3%
Output voltage range
110~120VAC
220~240VAC
Output frequency range
59.5~60.5HZ
49.5~50.5HZ
Input stage reverse
FUSE
FUSE
Output stage short circuit
YES
YES
Output overload range
110%~120% of rated power
110%~120% of rated power
Product over temperature
75~85ºC
75~85ºC
Others 
Input and output
grade
Completely isolated
Completely isolated
Dielectric strength
Input to output stage: 1.2KV/5mA  60S
Input to output stage: 1.2KV/5mA  60S
Output to shell: 1.2KV/5mA  60S
Output to shell: 1.2KV/5mA  60S
Full load work efficiency
≥90%
≥91%
≥92%
Working temperature of whole machine
Lower than environmental temperature +40ºC
Lower than environmental temperature +40ºC
Display mode
LCD display
LCD display
On/off mode
Button/Manual switch (optional)
Button/Manual switch (optional)
Cooling mode
Automatic thermostat fan cooling
Automatic thermostat fan cooling
Environment
Work temperature
 -10~+50ºC
Standard Comm. method
RS485
RS485
EMC
EN61000-3-2, EN50081
EN61000-3-2, EN50081
Protection degree
IP20
IP20