Product Main

Specifications

 
 
Full Servo pull up baby diaper machine
Technical Parameters:
Design production speed : 300pcs / min
Actual production speed : 200-250pcs /min
Power supply : as request
Power : about 250kw
Machine size : about 30m*7.5m*4.5m
Machine weight : 35T
Finished products : pull up baby diaper with 2 sides of right and left elastic tapes , acutal products according to clients demand .
Pass products : ≥ 97%.
Compress air : 0.6-0.9Mpa
Finished products specification : according to sample or designs ( confirmation by 2 parties ) , it can make S,M,L,XL size

Machine control :
A. The PLC-motion controller – Full Servo motor control system.
B. color touch screen was put in the security door frames of the equipment to facilitate production operations.
C. The main machine speed , the pulp feed rate, SAP quantity, tick waste, material feeding and stopping and cutter roller can be set and controlled on the touch screen
D. the speed of the machine , shift production , total production, downtime records and failure all will be displayed on the touch screen .
E. The transition of feeding and stopping materials automatically / manual can be set independently , You also can change the materials manually by buttons that are on the buttons station
F. temperature control with temperature controller
G. The drive of whole machine through servomotor
H. This machine with deviation-corrected system total 11 groups and with monitors and tick waist system .
I All raw materials, automatic detection and alarm shutdown.
J. Elastic-off material automatically detected.
K . The core material, non-woven on both sides of the intermediate non-woven, diversion layer non-woven upper toilet paper, the underlying composite membrane connector automatically.
L. Bilateral posted about the flexibility, the lack of automatic detection of bilateral magic button and tick waste.
M. electrical fault automatically shut down and automatically show the cause of the stored fault history.
N. Cotton core compaction winding automatic detection and alarm shutdown.
O. waste excluded the use of pneumatic auto-part manual control, and discharged by the guide plate