Product Description
HSFI&HESI Fault Indicator is installed on the overhead lines. When line fault comes, the line inspector can determine the fault section, fault branch and fault point quickly by the alarm display on the indicator. It changes completely the methods of blind line inspection and finding the fault area through switching on one area after another in the past. Thus, it reduces the area and time of power outage and improves the reliability of the power supply.
Principle of the Fault Indicator
Based on the embedded industrial MCU chip and at the same time using the adaptive technology and low power technology, HSFI&HESI series fault indicators were developed as a new generation of short-circuit & earth fault detecting and positioning products and are used in the transmission and distribution system, featured with strong anti-interference ability, low static power consumption and high reliability on detecting and indicating.
Short-circuit Fault Detection Principle
(1) Line running
(2) Tuning the value of the fault current automatically based on the load current (can also tuning the value of the fault current based on the requirement of the customer).When If/I0 makes a mutation and becomes larger than the tuning value (If is the fault current of the line, I0 is the load current of the line).
(3)Turn off the power supply (The voltage of the line is less than 3000V).
Earth Fault Detection Principle
(1) There is a sudden change on the transient line current, for example, the mean square root of the mutation on the line current in 3ms is larger than 15A
(2) The line voltage is less than 3000V for over 15s (this period can be tuned)
Features of the Fault Indicator
Quick in finding the fault: by addressing the fault line and fault range quickly, the fault can be found quickly so that to reduce the fault shooting time.
Fault indicating and reset: can issue the faults through alarming quickly when short-circuit or earth faults happen, and then reset according to the given method and setting time.
Low power: using the low power design to assure the long lifetime of the products.
High reliability and wide applicability: using the advanced adaptive technology design, the products can tuning the value of the fault current automatically according to the load current, so that the fault detection is highly reliable, stable, accurate and wide applicability.
Lithium Battery: using the imported Lithium battery, no need of the external power supply, and the power quality is stable and reliable.
High antiinterference capability: Using the advanced industrial chip and processing technology, the hardware part of the products has high anti-interference capability.
Simple structure: cast resin, sealed.
Easy installation: Both installation and disassembly can be done with special tools under power on state, no need to turn off the power supply.