2250TWS(H) fluid ends are standardized products of our company for matching with the model 2250/2000 power ends of fracturing truck produced by several fracturing equipment manufacturers in the world. It has excellent performance and long operating life.
Materials performance: in comply with the SAE 4330 V material standards of USA.
Design advantage: Autofrettaged fluid ends for extended service life, high wear-resisting, high pressure resistance, impact resistance.
Highest under pressure: 22500PSI(155.15Mpa)
Maximum flow: 815 gpm
Work strength: keeping high performance operation 10 hours every day, six days every week under harsh conditions.
Application: acidification treatment, high aggregate, high pressure, large displacement and fracturing operation under harsh conditions
Plunger
Diameter
In
|
Output Per Rev
GPR
|
Displacement at pump strokes per minute |
|||||||||
100
|
150
|
200
|
250
|
330
|
|||||||
GPM PSI
|
GPM PSI
|
GPM PSI
|
GPM PSI
|
GPM PSI
|
|||||||
4"
|
1.3
|
130
|
17,915
|
190
|
15,826
|
260
|
11,869
|
325
|
9,495
|
429
|
7,193
|
4.5"
|
1.65
|
165
|
14,115
|
248
|
12,444
|
330
|
9,352
|
413
|
7,472
|
545
|
5,662
|
5"
|
2.04
|
204
|
11,465
|
306
|
10,085
|
408
|
7,564
|
510
|
6,051
|
673
|
4,585
|
5.5"
|
2.47
|
247
|
9,475
|
371
|
8,318
|
494
|
6,247
|
618
|
4,994
|
815
|
3,787
|
braking power: BHP
|
1518
|
2000
|
2000
|
2000
|
2000
|
||||||
based on 90% mechanical efficiency and 100% volumetric efficiency. |