• • • Overview of Product • • •
MS350 anti - corrosive pressure transducer adopts German HELM made high – performance anti – corrosive tantalum membrane force – sensitive chip, supported with high – accuracy electronic element, and assembling with strict process flow. This series of product features strong corrosive resistance, wear resistance etc, which has very well solved the problems for pressure measurement of strong – and weak – corrosive gas or liquid under special domestic application.
• • • Features of Product • • •
1. Designed with tantalum membrane pressure resistant type chip, with very strong corrosive resistance
2. Impact – and vibration – proof, wear resistance
3. High accuracy: 0.25% FS 0.4% FS
4. Good stability: ≤0.2% FS / year, ≤0.2% FS / °C
5. Without production process pollution; without force transmission filling liquid
6. The enclosure may be made of PVC, titanium alloy or PTFE, depending on the customer’s corrosion of medium.
• • • Application of Product • • •
This series of pressure transducer may widely be used for such fields as petroleum, chemical, metallurgical, electric power, protection of environment etc to automatically measure and control the gauge pressure, absolute pressure, and negative pressure of corrosive gas, liquid, and vapor.
• • • Technical Data• • •
Measuring range
|
- 100KPa ~ 0 ~ 5KPa … 100KPa … 60MPa
|
||
Overloading capacity
|
Two times of FS pressure
|
||
Type of pressure
|
Gauge pressure or absolute pressure
|
||
Medium to be measured
|
Strong and weak corrosive gas or liquid
|
||
Overall accuracy
|
Typical: ± 0.25% FS
|
Maximum: ± 0.4% FS
|
|
Long – term stability
|
Typical: ± 0.1% FS / year
|
Maximum: ± 0.2% FS
|
|
Zero point temperature drifting
|
Typical: ± 0.015% FS Maximum: ± 0.03% FS
|
||
Full scale temperature drifting
|
Typical: ± 0.015% FS Maximum: ± 0.03% FS
|
||
Response time
|
≤3ms
|
||
Resolution
|
Infinite small (theoretical) 1 / 100000 (general)
|
||
Medium temperature
|
-20 ~ +85 °C
|
||
Compensating temperature
|
-10 ~ +60 °C
|
||
Ambient temperature
|
-20 ~ +80 °C
|
||
Material of membrane
|
Tantalum membrane
|
||
Material of enclosure
|
PVC, titanium alloy, PTFE
|
||
Load resistance
|
≤ (U-12) / 0.02Ω
|
||
Protection degree
|
IP 65 – IEC 60529 for plug type; IP 67 – IEC 60529 for cable type
|
||
Intrinsically safe explosion - proof
|
Ex ia II CT5
|
||
Insulation resistance
|
100MΩ, 500V DC
|
||
Weight
|
Approx. 250g
|
||
Vibrating tolerance
|
≤ ± 0.01% FS ( Axles X, Y , Z,200Hz / g )
|
||
Pressure connection
|
See product selection table and process connecting drawing (may be defined by the customer).
|
||
Electrical wiring connection
|
See product selection table and process connecting drawing (may be defined by the customer).
|