Product Main

Specifications

• • • Overview of Product • • •
 
MS326 ceramic capacitor pressure transducer adopts internationally advanced ceramic capacitor sensor, supported with high–accuracy electronic elements, and assembling with strict process. It adopts dry pressure measuring technology without intermediate liquid, thick membrane electronic technology, SMT (surface mount technology) and PFM signal transferring technology to fully play a role of technical advantages for ceramic capacitor sensor so as to make that the pressure transducer features excellent technical performance. It features strong anti–overloading and anti–impact capacity, high stability, and very high accuracy of measurement. This series of product may widely be used for such industrial fields as petroleum, chemical, metallurgical, electric power, pharmaceutical, and food etc.
 
• • • Features of Product • • •
 
1. Strong anti – overloading and anti – impact capacity, with over pressure up to several dozens to hundred times of scale
2. Adoption of imported ceramic capacitor sensor, with strong signal output, high comprehensive accuracy, and good stability
3.Small temperature drifting due to without intermediate liquid for measuring element
4. Wide range of pressure, from micro pressure 0.5kPa to high pressure 100MPa, with optional combined pressure with positive and negative pressure
5. Pure ceramic substrate will not result process pollution. It applies to food and medical industrial.
6. Strong disturbance immunity, water – proof, dust – proof, vibration – proof, explosion – proof, and corrosion – proof.
7. Intrinsically safe explosion – proof, with explosion – proof Class Ex ia II CT5
 
 
• • • Application of Product • • •
 
This series of product may widely be used for such industrial fields as petroleum, chemical, metallurgical, electric power, pharmaceutical, and food etc.  
 
• • • Technical Data• • •
 
Measuring range
-100KPa ~ 0 ~ 5KPA…100MPa
Overloading capacity
3 ~ 200 times of maximum rated pressure (the smaller scale, the bigger over pressure times
Type of pressure
Gauge pressure, absolute pressure
Medium to be measured
Corrosive liquid, gas, and vapor (the medium compatible with AL2O3 and 1Cr18Ni9Ti)
Overall accuracy
Non - linear, repeatability, lagging
± 0.1% FS
± 0.25% FS
± 0.5% FS
Medium temperature
-40~+125°C
 
Ambient temperature
-40~+85°C
 
Compensating temperature
-20~+80°C
 
Long – term stability
± 0.1% FS / year
Zero point temperature drifting
± 0.02% FS / °C/Maximum: ± 0.05% FS / °C
Sensitivity temperature drifting
± 0.02% FS / °C/Maximum: ±0.05% FS / °C
Range of power supplying
12 ~ 36V DC ( generally 24V DC)
Signal output
4~20mA / 1-5V DC / 0~5V DC/0.5~4.5VDC
Load resistance
≤(U - 12) / 0.02Ω
Material of structure
Membrane: AL2O3 ceramic
Enclosure: Cast aluminum with low copper content
Connecting material: 1Cr18Ni9Ti
Sealing structure: NBR, PTFE or Fluorubber
Safe explosion – proof
Ex ia II CT5
Enclosure protection degree
IP65
Response time (10% ~ 90%)
≤3ms
Weight
Approx. 500g
Tolerance of vibration
≤ ± 0.01% FS(Axles X, Y, and Z, 200Hz / g)
Signal wire connecting hole
Cable hole is¢8
Dielectric strength / RF degree
EN 50081–1; EN 50082–2; IEC 61000–4–3
Pressure connection
See product selection table and process connecting drawing (may be defined by the customer).
Electrical wiring connection
See product selection table and process connecting drawing (may be defined by the customer).