• • • Overview of Product • • •
MS326 ceramic capacitor pressure transducer adopts internationally advanced ceramic capacitor sensor, supported with high–accuracy electronic elements, and assembling with strict process. It adopts dry pressure measuring technology without intermediate liquid, thick membrane electronic technology, SMT (surface mount technology) and PFM signal transferring technology to fully play a role of technical advantages for ceramic capacitor sensor so as to make that the pressure transducer features excellent technical performance. It features strong anti–overloading and anti–impact capacity, high stability, and very high accuracy of measurement. This series of product may widely be used for such industrial fields as petroleum, chemical, metallurgical, electric power, pharmaceutical, and food etc.
• • • Features of Product • • •
1. Strong anti – overloading and anti – impact capacity, with over pressure up to several dozens to hundred times of scale
2. Adoption of imported ceramic capacitor sensor, with strong signal output, high comprehensive accuracy, and good stability
3.Small temperature drifting due to without intermediate liquid for measuring element
4. Wide range of pressure, from micro pressure 0.5kPa to high pressure 100MPa, with optional combined pressure with positive and negative pressure
5. Pure ceramic substrate will not result process pollution. It applies to food and medical industrial.
6. Strong disturbance immunity, water – proof, dust – proof, vibration – proof, explosion – proof, and corrosion – proof.
7. Intrinsically safe explosion – proof, with explosion – proof Class Ex ia II CT5
• • • Application of Product • • •
This series of product may widely be used for such industrial fields as petroleum, chemical, metallurgical, electric power, pharmaceutical, and food etc.
• • • Technical Data• • •
Measuring range
|
-100KPa ~ 0 ~ 5KPA…100MPa
|
|||
Overloading capacity
|
3 ~ 200 times of maximum rated pressure (the smaller scale, the bigger over pressure times
|
|||
Type of pressure
|
Gauge pressure, absolute pressure
|
|||
Medium to be measured
|
Corrosive liquid, gas, and vapor (the medium compatible with AL2O3 and 1Cr18Ni9Ti)
|
|||
Overall accuracy
Non - linear, repeatability, lagging
|
± 0.1% FS
|
± 0.25% FS
|
± 0.5% FS
|
|
Medium temperature
|
-40~+125°C
|
|
||
Ambient temperature
|
-40~+85°C
|
|
||
Compensating temperature
|
-20~+80°C
|
|
||
Long – term stability
|
± 0.1% FS / year
|
|||
Zero point temperature drifting
|
± 0.02% FS / °C/Maximum: ± 0.05% FS / °C
|
|||
Sensitivity temperature drifting
|
± 0.02% FS / °C/Maximum: ±0.05% FS / °C
|
|||
Range of power supplying
|
12 ~ 36V DC ( generally 24V DC)
|
|||
Signal output
|
4~20mA / 1-5V DC / 0~5V DC/0.5~4.5VDC
|
|||
Load resistance
|
≤(U - 12) / 0.02Ω
|
|||
Material of structure
|
Membrane: AL2O3 ceramic
|
Enclosure: Cast aluminum with low copper content
|
||
Connecting material: 1Cr18Ni9Ti
|
Sealing structure: NBR, PTFE or Fluorubber
|
|||
Safe explosion – proof
|
Ex ia II CT5
|
|||
Enclosure protection degree
|
IP65
|
|||
Response time (10% ~ 90%)
|
≤3ms
|
|||
Weight
|
Approx. 500g
|
|||
Tolerance of vibration
|
≤ ± 0.01% FS(Axles X, Y, and Z, 200Hz / g)
|
|||
Signal wire connecting hole
|
Cable hole is¢8
|
|||
Dielectric strength / RF degree
|
EN 50081–1; EN 50082–2; IEC 61000–4–3
|
|||
Pressure connection
|
See product selection table and process connecting drawing (may be defined by the customer).
|
|||
Electrical wiring connection
|
See product selection table and process connecting drawing (may be defined by the customer).
|