Product Main

Specifications

Application: 
CAMB series Moulded case circuit breaker (MCCB) is suitable for circuit AC 50/60Hz, rated voltage up to AC 660V, rated operating current to 630V. 

It features normal structure, reliable performance, complete accessories & high breaking capacity, used for power distribution and protecting the circuit and electrical equipment against overload short circuit. It complies with standard of IEC947-2. DD. 

Rated Current: 
CAMB-125S 12.5A, 16A, 20A, 25A, 32A, 40A, 50A, 63A, 80A, 100A, 125A. 
CAMB-160S 16A, 20A, 32A, 40A, 50A, 63A, 80A, 100A, 125A, 160A 
CAMB-250S 100A, 125A, 160A, 180A, 200A, 225A, 250A 
CAMB-400S 200A, 225A, 250A, 315A, 350A, 400A 
CAMB-630S 400A, 500A, 630A 
CAMB-800S 500A, 630A, 700A, 800A 
NO. Of Pole: 3Pole, 4Pole 
Rated operating Voltage: 380V, 660V
Rated current of release (A) Thermodynamc release (ambient temp +40ºC) Operational Current of Magnetic Release (A)
1.05In(cold state)
operative time (h)
1.30In(heat state)
operative time(h)
In≤63 ≥1 <1 10In±20%
63<In≤100 ≥2 <2 10In±20%
100<In≤630 ≥2 <2 5-10In±20%









Rated current of relaese (A)                            Thermodynamic release
                             (ambient temp +40ºC)
 Operational Current of Magnetic Release (A)
 1.0In(cold state)
inoperative time
 1.20In(cold state)
inoperative time
 1.50IN(cold state)
inoperative time
 7.20In(cold state)
inoperative time
 12.5≤In≤400  ≥2h <2h ≤4min  2s<Tp≤10sh  12In±20%









 

Type
 

Rated Current (A)
 
Pole number
 Ultimate Short Circuit Breaking Capacity(KA)  Service Short Circuit Breaking Cpacity (kA) Operation Performance  Overall dimensions   Rated insulation Voltage (V)  Rated operating voltage(V)
AC380V
(400)
AC660V
(690)
DC250 AC380V
(400)
AC660V
(690)
Load Unload L W3P
/4P
H
CAMB-125E  12.5,16,20,25,32,
40,50,63,80,100,125
 2,3,4 Pole  15 - -  7.5 -  3000 7000  120 76/101  70  660V  380V
 660V
CAMB-125S 25 - 20 16 -
CAMB-160S  16,20,32,40,50,
63,80,100,125,160
  2,3,4 Pole  35 8 20  18 -  4000 6000  120 90/120  70  660V  380V
 660V
CAMB-160H 50 10 40  25 -
CAMB-250S  100,125,160,180,
200,225,250
  2,3,4 Pole  35 10 40  18 -  2000 6000  170 105/140  103.5  660V  380V
 660V
CAMB-250M 50 16 40 30 -
CAMB-250H 65 18 40 48 -
CAMB-400S  200,225,250,315,
350,400
  2,3,4 Pole  35 16 40  18 -  1000 4000  254 140/184  103.5  660V  380V
 660V
CAMB-400M 50 20 40 30 -
CAMB-400H 65 25 40 48 -
CAMB-630S  400,500,630   2,3,4 Pole  50 20 40  30 -  1000 4000  268 210/280  103.5  660V  380V
 660V
CAMB-630M 65 25 40 48 -
CAMB-630H 80 30 40 60 -
CAMB-800S  500,630,700,800   2,3,4 Pole  50 20 40  30 -  1000 4000  268 210/280  103.5  660V  380V
 660V
CAMB-800M 65 25 40 48 -
CAMB-800H 80 30 40 60