1. Specification
* Specification: 4P
* Rated Temperature: -20°C ~ + 75°C
* Unshielded twisted pairs
* Conductor: 23AWG or 24AWG Stranding or Solid Bare copper
* Insulation: HDPE
* Filler: PE Cross or FM-PE Thin slice
* Rip cord: optional
* Jacket: PVC or LSNH
* Impedance: 100±15% Ω at 1 ~250MHz
* Reference Standard: ANSI/TIA/EIA-568B, ISO/IEC11801
2. Application
Mainly Used In The Building Correspondence Synthesis Wiring System The Work Area Correspondence Leading-out Terminal and between the Connection Distribution Frame Wiring, As Well As the Housing Synthesis Wiring System’s User Correspondence Leading-out Terminal Arrives at Place of Exile between Coils’ wiring.
Cable assembly specification:
Conductor
|
Insulation
|
Core Number
|
Filler
|
Jacket
|
||||
AWG
|
Specification
mm
|
Material
|
Thickness
(NOM.mm)
|
Material
|
Thickness
(NOM.mm)
|
OD
(NOM.mm)
|
||
23
|
1/0.573
|
HD-PE
|
0.18
|
4P
|
PE Cross
|
PVC or LSNH
|
0.60
|
7.0
|
24
|
1/0.511
|
HD-PE
|
0.18
|
4P
|
PE Cross
|
PVC or LSNH
|
0.60
|
6.5
|
26
|
1/0.404
|
HD-PE
|
0.18
|
4P
|
PE Cross
|
PVC or LSNH
|
0.60
|
6.0
|
Electrical characteristics
Frequency
Mhz |
Impedance
ohm |
RL
≥dB |
Attenuation
≤dB/100m |
NEXT
≥dB/100m |
1
|
100±15
|
20.0
|
1.9
|
74.3
|
4
|
100±15
|
23.0
|
3.7
|
65.3
|
10
|
100±15
|
25.0
|
5.9
|
59.3
|
16
|
100±15
|
25.0
|
7.5
|
56.0
|
20
|
100±15
|
25.0
|
8.4
|
54.8
|
25
|
100±15
|
25.3
|
9.5
|
53.3
|
31.25
|
100±15
|
23.6
|
10.6
|
52
|
62.5
|
100±15
|
21.5
|
15.4
|
47
|
100
|
100±15
|
20.1
|
19.8
|
44
|
200
|
100±18
|
18.0
|
29.0
|
40
|
250
|
100±18
|
17.3
|
32.8
|
38.3
|
*300
|
100±22
|
16.8
|
36.4
|
37.1
|
*500
|
100±22
|
15.2
|
48.9
|
33.8
|