Orifice Flow Meter 
 

 

Pipeline
bore (mm)
Throttling
element
1st choice (set)
50, 80, 100, 125, 150, 200, 250, 300
2nd choice
(25), 65, 175, 225, 275, 325
Throttling β
Standard orifice
0.44, 0.52, 0.65
Material
1st choice: 1Cr18Ni9Ti;          2nd choice: 2Cr13
Temperature range
Water
Environment temperature
0 ~ 50℃
Application temperature
0 ~ 100℃
Dry gas
0 ~ 50℃
-25 ~ 200℃
Wet gas
0 ~ 50℃
0 ~ 500℃
Steam
0 ~ 50℃
100 ~ 450℃
Pressure range
Nominal pressure: 2.5MPa, 4.0MPa
Relative Humidity
≤95%
Flowing range
Same as the traditional standard orifice flow meter
Accuracy
1%
Protection level
IP65
Power supply
24VDC
Holding part material
20# steel, A3 steel (optional), 1Cr18Ni9Ti (optional) 
All in one standard orifice flow meter is one kind of differential pressure flow meter which fitted with standard orifice throttling element. It has long history; plenty reference material on both theory and practice, mature on usage. It is the most popular flow meter which widely used in many field.

The throttling element of standard orifice flow meter is strictly following the international standard for design, manufacture, installation and operation. It doesn’t require real-calibration for flow rate measuring or estimating the inaccuracy. It is widely used in many industry fields as petroleum, chemical, power, textile, metallurgical, military and scientific research.